A noninvasive, three-dimensional spinal motion analysis method

被引:26
作者
Lim, TH [1 ]
Eck, JC [1 ]
An, HS [1 ]
McGrady, LM [1 ]
Harris, GF [1 ]
Haughton, VM [1 ]
机构
[1] MED COLL WISCONSIN,DEPT RADIOL,MILWAUKEE,WI 53226
关键词
moment of inertia; motion analysis; principal axis; spine;
D O I
10.1097/00007632-199709010-00011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A three-dimensional, noninvasive motion analysis method was developed by monitoring the orientation of the principal axes of each vertebra. Objectives. To develop a method of performing three-dimensional, noninvasive motion analysis of the spine using computed tomography data. Summary of Background Data. The concept of using principal axes of the moment of inertia tensor to measure the orientation and position of a rigid body has been applied to the wrist and subtalar joints, but has not yet been applied to the spine. Methods. Scans were taken of two isolated vertebrae in various known positions. Centroids, area, moments, and product of inertia of each scan were determined using a commercial program. Custom software combined data using the parallel axis theorem to give three-dimensional data for each vertebra. Changes in the centroid and principal axes were used to calculate translation and rotation? respectively. Results. The system accuracy was within 1.0 degrees in rotation and 1.0 mm in translation. Some errors occurred in minor motions when a smaller number of scans were used System resolution was 0.43 mm. Conclusions. A system has been developed capable of calculating three-dimensional spinal motion based on measurements of a series of computed tomography images. The system has an accuracy similar to that of current motion analysis methods, but future studies will be necessary to apply this system in vivo.
引用
收藏
页码:1996 / 2000
页数:5
相关论文
共 25 条
[11]   THE USE OF MAGNETIC-RESONANCE IMAGING FOR MEASURING SEGMENT INERTIAL PROPERTIES [J].
MARTIN, PE ;
MUNGIOLE, M ;
MARZKE, MW ;
LONGHILL, JM .
JOURNAL OF BIOMECHANICS, 1989, 22 (04) :367-&
[12]   ESTIMATING SEGMENT INERTIAL PROPERTIES - COMPARISON OF MAGNETIC-RESONANCE-IMAGING WITH EXISTING METHODS [J].
MUNGIOLE, M ;
MARTIN, PE .
JOURNAL OF BIOMECHANICS, 1990, 23 (10) :1039-1046
[13]  
PANJABI MM, 1969, SPINE, V17, P200
[14]   3-DIMENSIONAL X-RAY-ANALYSIS OF NORMAL MOVEMENT IN THE LUMBAR SPINE [J].
PEARCY, M ;
PORTEK, I ;
SHEPHERD, J .
SPINE, 1984, 9 (03) :294-297
[15]   DYNAMIC BACK MOVEMENT MEASURED USING A 3-DIMENSIONAL TELEVISION SYSTEM [J].
PEARCY, MJ ;
GILL, JM ;
WHITTLE, MW ;
JOHNSON, GR .
JOURNAL OF BIOMECHANICS, 1987, 20 (10) :943-949
[16]  
PENNING L, 1987, AM J ROENTGENOL, V30, P317
[17]   EVALUATION OF EULER ANGLES WITH A LEAST-SQUARES METHOD FOR THE STUDY OF LUMBAR SPINE MOTION [J].
PLAMONDON, A ;
GAGNON, M .
JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (02) :143-149
[18]   THE RESPONSE OF THE SEATED HUMAN TO SINUSOIDAL VIBRATION AND IMPACT [J].
POPE, MH ;
WILDER, DG ;
JORNEUS, L ;
BROMAN, H ;
SVENSSON, M ;
ANDERSSON, G .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (04) :279-284
[19]   EXAMINING MOTION IN THE CERVICAL-SPINE .2. CHARACTERIZATION OF COUPLED JOINT MOTION USING AN OPTOELECTRONIC DEVICE TO TRACK SKIN MARKERS [J].
ROOZMON, P ;
GRACOVETSKY, SA ;
GOUW, GJ ;
NEWMAN, N .
JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (01) :13-22
[20]   EXAMINING MOTION IN THE CERVICAL-SPINE .1. IMAGING-SYSTEMS AND MEASUREMENT TECHNIQUES [J].
ROOZMON, P ;
GRACOVETSKY, SA ;
GOUW, GJ ;
NEWMAN, N .
JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (01) :5-12