A simple method for obtaining highly accurate Pb isotope data by MC-ICP-MS

被引:197
作者
Woodhead, J [1 ]
机构
[1] Univ Melbourne, Sch Earth Sci, Parkville, Vic 3010, Australia
关键词
D O I
10.1039/b205045e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Many recent studies of isotope ratio determination by multi- collector inductively coupled plasma mass spectrometry ( MC- ICP- MS) have highlighted the excellent levels of analytical precision obtainable using this newly emergent technology. Unfortunately, it is often a considerably more difficult matter to obtain highly accurate analyses by MC- ICP- MS. This is particularly the case for isotope systems in which internal normalisation for instrumental mass bias effects is not possible, e. g., Pb, Cu, Zn, B, Li. Given the fact that extremely accurate Pb isotope data can now be obtained by double- spike thermal ionisation mass spectrometry ( TIMS), this is seemingly a major impediment to the widespread adoption of MC- ICP- MS methods for the analysis of Pb. It is demonstrated in this contribution, however, that a few simple modi cations to existing protocols can produce MC- ICP- MS Pb isotope data of comparable accuracy to the best double spike TIMS results. This method also preserves many of the inherent advantages of ICP- MS analysis, such as rapid sample processing, and avoids many of the stringent analytical requirements of double spiking. The method is highly reliable and a summary of results from our laboratory over the past two years is presented, together with suggestions for further development.
引用
收藏
页码:1381 / 1385
页数:5
相关论文
共 25 条
[1]   Improving boron isotope ratio measurement precision with quadrupole inductively coupled plasma-mass spectrometry [J].
Al-Ammar, A ;
Reitznerová, E ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (12) :1861-1867
[2]   Correction for non-spectroscopic matrix effects in inductively coupled plasma-mass spectrometry by common analyte internal standardization [J].
Al-Ammar, AS ;
Gupta, RK ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (13) :1849-1860
[3]   A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes [J].
Belshaw, NS ;
Freedman, PA ;
O'Nions, RK ;
Frank, M ;
Guo, Y .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :51-58
[4]   ABSOLUTE ISOTOPIC ABUNDANCE AND THE ATOMIC WEIGHT OF A REFERENCE SAMPLE OF THALLIUM [J].
DUNSTAN, LP ;
GRAMLICH, JW ;
BARNES, IL ;
PURDY, WC .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1980, 85 (01) :1-10
[5]  
Gale N. H., 1970, CHEM GEOL, V6, P305
[6]  
Galer S. J. G., 1998, MINERAL MAG A, V62, P491, DOI DOI 10.1180/MINMAG.1998.62A.1.260
[7]   RECENT DEVELOPMENTS IN INDUCTIVELY-COUPLED PLASMA MAGNETIC-SECTOR MULTIPLE COLLECTOR MASS-SPECTROMETRY [J].
HALLIDAY, AN ;
LEE, DC ;
CHRISTENSEN, JN ;
WALDER, AJ ;
FREEDMAN, PA ;
JONES, CE ;
HALL, CM ;
YI, W ;
TEAGLE, D .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 146 :21-33
[8]   PRECISE LEAD ISOTOPE MEASUREMENTS BY THE DOUBLE SPIKE TECHNIQUE - A RECONSIDERATION [J].
HAMELIN, B ;
MANHES, G ;
ALBAREDE, F ;
ALLEGRE, CJ .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1985, 49 (01) :173-182
[9]   Lead isotopic analyses of NIST standard reference materials using multiple collector inductively coupled plasma mass spectrometry coupled with a modified external correction method for mass discrimination effect [J].
Hirata, T .
ANALYST, 1996, 121 (10) :1407-1411
[10]   FRACTIONATION CORRECTIONS FOR MIXED-ISOTOPE SPIKES OF SR, K, AND PB [J].
HOFMANN, A .
EARTH AND PLANETARY SCIENCE LETTERS, 1971, 10 (04) :397-&