Detecting Glaucoma With a Portable Brain-Computer Interface for Objective Assessment of Visual Function Loss

被引:65
作者
Nakanishi, Masaki [1 ]
Wang, Yu-Te [2 ]
Jung, Tzyy-Ping [2 ]
Zao, John K. [3 ]
Chien, Yu-Yi [2 ,3 ]
Diniz-Filho, Alberto [1 ]
Daga, Fabio B. [1 ]
Lin, Yuan-Pin [2 ]
Wang, Yijun [2 ]
Medeiros, Felipe A. [1 ]
机构
[1] Univ Calif San Diego, Visual Performance Lab, 9500 Gilman Dr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Swartz Ctr Computat Neurosci, La Jolla, CA 92093 USA
[3] Natl Chiao Tung Univ, Dept Comp Sci, Hsinchu, Taiwan
基金
美国国家卫生研究院;
关键词
INDEPENDENT COMPONENT ANALYSIS; EVOKED POTENTIALS; MULTIFOCAL VEP; OPTIC DISC; DAMAGE; PERIMETRY; DYNAMICS; ARTIFACTS; WALKING; FIELD;
D O I
10.1001/jamaophthalmol.2017.0738
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IMPORTANCE The current assessment of visual field loss in diseases such as glaucoma is affected by the subjectivity of patient responses and the lack of portability of standard perimeters. OBJECTIVE To describe the development and initial validation of a portable brain-computer interface (BCI) for objectively assessing visual function loss. DESIGN, SETTING, AND PARTICIPANTS This case-control study involved 62 eyes of 33 patients with glaucoma and 30 eyes of 17 healthy participants. Glaucoma was diagnosed based on a masked grading of optic disc stereophotographs. All participants underwent testing with a BCI device and standard automated perimetry (SAP) within 3 months. The BCI device integrates wearable, wireless, dry electroencephalogram and electrooculogram systems and a cellphone-based head-mounted display to enable the detection of multifocal steady state visual-evoked potentials associated with visual field stimulation. The performances of global and sectoral multifocal steady state visual-evoked potentials metrics to discriminate glaucomatous from healthy eyes were compared with global and sectoral SAP parameters. The repeatability of the BCI device measurements was assessed by collecting results of repeated testing in 20 eyes of 10 participants with glaucoma for 3 sessions of measurements separated by weekly intervals. MAIN OUTCOMES AND MEASURES Receiver operating characteristic curves summarizing diagnostic accuracy. Intraclass correlation coefficients and coefficients of variation for assessing repeatability. RESULTS Among the 33 participants with glaucoma, 19 (58%) were white, 12 (36%) were black, and 2 (6%) were Asian, while among the 17 participants with healthy eyes, 9 (53%) were white, 8 (47%) were black, and none were Asian. The receiver operating characteristic curve area for the global BCI multifocal steady state visual-evoked potentials parameter was 0.92 (95% CI, 0.86-0.96), which was larger than for SAP mean deviation (area under the curve, 0.81; 95% CI, 0.72-0.90), SAP mean sensitivity (area under the curve, 0.80; 95% CI, 0.69-0.88; P = .03), and SAP pattern standard deviation (area under the curve, 0.77; 95% CI, 0.66-0.87; P = .01). No statistically significant differences were seen for the sectoral measurements between the BCI and SAP. Intraclass coefficients for global and sectoral parameters ranged from 0.74 to 0.92, and mean coefficients of variation ranged from 3.03% to 7.45%. CONCLUSIONS AND RELEVANCE The BCI device may be useful for assessing the electrical brain responses associated with visual field stimulation. The device discriminated eyes with glaucomatous neuropathy from healthy eyes in a clinically based setting. Further studies should investigate the feasibility of the BCI device for home-based testing as well as for detecting visual function loss over time.
引用
收藏
页码:550 / 557
页数:8
相关论文
共 45 条
[1]   Contrast-response functions of the multifocal steady-state VEP (MSV) [J].
Abdullah, S. N. ;
Vaegan ;
Boon, M. Y. ;
Maddess, T. .
CLINICAL NEUROPHYSIOLOGY, 2012, 123 (09) :1865-1871
[2]   Effect of Contrast, Stimulus Density, and Viewing Distance on Multifocal Steady-State Visual Evoked Potentials (MSVs) [J].
Abdullah, Siti N. ;
Aldahlawi, Nada ;
Rosli, Yanti ;
Vaegan ;
Boon, Mei Ying ;
Maddess, Ted .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (09) :5527-5535
[3]  
[Anonymous], 2010, IEEE REV BIOMED ENG, DOI DOI 10.1109/RBME.2010.2084078
[4]   An online multi-channel SSVEP-based brain-computer interface using a canonical correlation analysis method [J].
Bin, Guangyu ;
Gao, Xiaorong ;
Yan, Zheng ;
Hong, Bo ;
Gao, Shangkai .
JOURNAL OF NEURAL ENGINEERING, 2009, 6 (04)
[5]   Practical recommendations for measuring rates of visual field change in glaucoma [J].
Chauhan, B. C. ;
Garway-Heath, D. F. ;
Goni, F. J. ;
Rossetti, L. ;
Bengtsson, B. ;
Viswanathan, A. C. ;
Heijl, A. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (04) :569-573
[6]   High-speed spelling with a noninvasive brain-computer interface [J].
Chen, Xiaogang ;
Wang, Yijun ;
Nakanishi, Masaki ;
Gao, Xiaorong ;
Jung, Tzyy-Ping ;
Gao, Shangkai .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2015, 112 (44) :E6058-E6067
[7]   EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis [J].
Delorme, A ;
Makeig, S .
JOURNAL OF NEUROSCIENCE METHODS, 2004, 134 (01) :9-21
[8]   Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis [J].
Delorme, Arnaud ;
Sejnowski, Terrence ;
Makeig, Scott .
NEUROIMAGE, 2007, 34 (04) :1443-1449
[9]   Mapping the visual field to the optic disc in normal tension glaucoma eyes [J].
Garway-Heath, DF ;
Poinoosawmy, D ;
Fitzke, FW ;
Hitchings, RA .
OPHTHALMOLOGY, 2000, 107 (10) :1809-1815
[10]   Multifocal objective perimetry in the detection of glaucomatous field loss [J].
Goldberg, I ;
Graham, SL ;
Klistorner, AI .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (01) :29-39