CT-guided intervention using a patient laser marker system

被引:21
作者
Kloeppel, R
Weisse, T
Deckert, F
Wilke, W
Pecher, S
机构
[1] Univ Hosp Leipzig, Dept Diagnost Radiol, D-04103 Leipzig, Germany
[2] Univ Hosp Leipzig, Dept Radiotherapy & Radiooncol, D-04103 Leipzig, Germany
关键词
interventional radiology; computed tomography; CT-guided biopsy; laser guidance; quality assurance;
D O I
10.1007/s003300051054
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To prove the usefulness of a simple laser marker system (LMS) in target definition as well as examination procedure for CT-guided interventions, 130 cases of diagnostic biopsies and lumbal sympathectomies were compared. In 75 cases LMS and in 55 cases a simple crossgrid was used. Taking advantage of the LMS, the parameters of intervention (cutaneous location, length, and angle) can be planned, exactly demonstrated, and it is possible to check the needle position during the whole procedure. Thus, the number of necessary control scans decreased to 30 %, and corrections of needle location were reduced to approximately 30 %. Moreover, the average target deviation of the needle decreased below 5 mm in 50 % of cases, and the duration of interventional procedure was reduced considerably. It can be concluded that LMSs are recommended in CT-guided interventions for quality assurance, dose reduction, and improvement of handling. It will be especially advantageous in cases of small target volume, oblique needle path, and tilted gantry.
引用
收藏
页码:1010 / 1014
页数:5
相关论文
共 17 条
[1]   Evaluation of biopsy needles and prototypic needle guide devices for percutaneous biopsy with CT fluoroscopic guidance in simulated organ tissue [J].
Daly, B ;
Templeton, PA ;
Krebs, TL ;
Carroll, K ;
Wong-You-Cheong, JJ .
RADIOLOGY, 1998, 209 (03) :850-855
[2]   A NEW LASER GUIDANCE-SYSTEM FOR CT-GUIDED AND MR-GUIDED PROCEDURES FOR THE BODY [J].
FRAHM, C ;
KLOESS, W ;
GEHL, HB ;
WEISS, HD .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 163 (01) :73-76
[3]   A LIGHT-GUIDANCE SYSTEM TO BE USED FOR CT-GUIDED BIOPSY [J].
FREDERICK, PR ;
BROWN, TH ;
MILLER, MH ;
BAHR, AL ;
TAYLOR, KH .
RADIOLOGY, 1985, 154 (02) :535-536
[4]  
FROHLICH JJ, 1999, ROFO FORTSCHR RONTG, V170, P191
[5]   A COMPACT LASER-BEAM GUIDANCE-SYSTEM FOR INTERVENTIONAL CT [J].
GANGI, A ;
KASTLER, B ;
ARHAN, JM ;
KLINKERT, A ;
GRAMPP, JM ;
DIETEMANN, JL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :326-328
[6]  
JACOBI V, 1995, STRAHLENTHER ONKOL, V171, P88
[7]   Real-time CT fluoroscopy: Usefulness in thoracic drainage [J].
Meyer, CA ;
White, CS ;
Wu, J ;
Futterer, SF ;
Templeton, PA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (04) :1097-1101
[8]   LASER GUIDANCE-SYSTEM FOR CT-GUIDED PROCEDURES [J].
MIAUX, Y ;
GUERMAZI, A ;
GOSSOT, D ;
BOURRIER, P ;
ANGOULVANT, D ;
KHAIROUNE, A ;
TURKI, C ;
BOUCHE, E .
RADIOLOGY, 1995, 194 (01) :282-284
[9]   Technical aspects of needle aspiration lung biopsy: A personal perspective [J].
Moore, EH .
RADIOLOGY, 1998, 208 (02) :303-318
[10]   Special techniques in CT-guided transthoracic needle biopsy [J].
Nashed, Z ;
Klein, JS ;
Zarka, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (06) :1665-1668