Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization

被引:144
作者
Gupta, Rajiv
Grasruck, Michael
Suess, Christoph
Bartling, Soenke H.
Schmidt, Bernhard
Stierstorfer, Karl
Popescu, Stefan
Brady, Tom
Flohr, Thomas
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Siemens Med Solut, Forchheim, Germany
[3] Hannover Med Sch, Dept Neuroradiol, D-3000 Hannover, Germany
关键词
CT; flat-panel detector; high resolution; volume CT; Dose;
D O I
10.1007/s00330-006-0156-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital flat-panel-based volume CT (VCT) represents a unique design capable of ultra-high spatial resolution, direct volumetric imaging, and dynamic CT scanning. This innovation, when fully developed, has the promise of opening a unique window on human anatomy and physiology. For example, the volumetric coverage offered by this technology enables us to observe the perfusion of an entire organ, such as the brain, liver, or kidney, tomographically (e.g., after a transplant or ischemic event). By virtue of its higher resolution, one can directly visualize the trabecular structure of bone. This paper describes the basic design architecture of VCT. Three key technical challenges, viz., scatter correction, dynamic range extension, and temporal resolution improvement, must be addressed for successful implementation of a VCT scanner. How these issues are solved in a VCT prototype and the modifications necessary to enable ultra-high resolution volumetric scanning are described. The fundamental principles of scatter correction and dose reduction are illustrated with the help of an actual prototype. The image quality metrics of this prototype are characterized and compared with a multi-detector CT (MDCT).
引用
收藏
页码:1191 / 1205
页数:15
相关论文
共 16 条
[1]  
BARTLING S, 2002, ROFO FORTSCHR GE S1, V174, P249
[2]  
BARTLING S, 2002, J NEURORADIOLOGY, V29, P175
[3]   High-resolution computed tomography of temporal bone Part II: Coronal preoperative anatomy [J].
Bartling, SH ;
Shukla, V ;
Becker, H ;
Brady, TJ ;
Hayman, A ;
Gupta, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (04) :566-569
[4]   High-resolution flat-panel volume-CT of temporal bone - Part 1 - Axial preoperative anatomy [J].
Bartling, SH ;
Shukla, V ;
Becker, H ;
Brady, TJ ;
Hayman, A ;
Gupta, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (03) :420-423
[5]   Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey [J].
Brix, G ;
Nagel, HD ;
Stamm, G ;
Veit, R ;
Lechel, U ;
Griebel, J ;
Galanski, M .
EUROPEAN RADIOLOGY, 2003, 13 (08) :1979-1991
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]   Evaluation of image quality and dose on a flat-panel CT-scanner [J].
Grasruck, M ;
Suess, C ;
Stierstorfer, K ;
Popescu, S ;
Flohr, T .
Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 :179-188
[8]  
Gupta R, 2004, AM J NEURORADIOL, V25, P1417
[9]   Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience [J].
Nikolaou, K ;
Flohr, T ;
Stierstorfer, K ;
Becker, CR ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2005, 15 (02) :329-333
[10]   Flat-panel volumetric Computed Tomography - A new method for visualizing fine bone detail in living mice [J].
Obert, M ;
Ahlemeyer, B ;
Baumgart-Vogt, E ;
Traupe, H .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (04) :560-565