In vitro acoustic characterisation of four intravenous ultrasonic contrast agents at 30 MHz

被引:46
作者
Moran, CM
Watson, RJ
Fox, KAA
McDicken, WN
机构
[1] Univ Edinburgh, Royal Infirm Edinburgh, Dept Med Phys & Med Engn, Edinburgh EH3 9YW, Midlothian, Scotland
[2] Univ Edinburgh, Royal Infirm Edinburgh, Dept Cardiol, Edinburgh EH3 9YW, Midlothian, Scotland
关键词
contrast agent; high-frequency; acoustic characterisation; SonoVue (TM); Sonazoid (TM); Optison (TM); Definity (TM);
D O I
10.1016/S0301-5629(02)00520-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The acoustic properties of four ultrasonic contrast agents (Optison(TM), Definity(TM), SonoVue(TM) and Sonazoid(TM)) were studied at 30 MHz using a Boston Scientific ClearView Ultra intravascular ultrasound (US) scanner modified to allow access to the unprocessed US data. A range of contrast agent concentrations were studied using either saline or glucose as the diluent of choice. Mean backscatter power was measured over regions-of-interest (ROI) at distances of 1, 1.5, 2, 3, 4 and 5 mm from the centre of the intravascular probe and normalised to the US data collected from a standard glass reflector. For all of the agents, the mean backscatter power at 30 MHz varied in a linear manner with concentration between 0.01 million microbubbles/mL and 1 million microbubbles/mL. Furthermore, for two of the agents, mean backscatter enhancement was detectable at concentrations as low as 2 microbubbles/sample volume. (E-mail:carmel.moran@ed.ac.uk) (C) 2002 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 36 条
[1]  
ALLEN JS, 2002, 7 EUR S ULTR CONTR I
[2]   ULTRASONIC CHARACTERIZATION OF ALBUNEX, A NEW CONTRAST AGENT [J].
BLEEKER, HJ ;
SHUNG, KK ;
BARNHART, JL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (04) :1792-1797
[3]  
BOUAKAZ A, 1996, IEEE ULTRASON S P, P1445
[4]   Ultrasound contrast agent in intravascular echography: An in vitro study [J].
Cachard, C ;
Finet, G ;
Bouakaz, A ;
Tabib, A ;
Francon, D ;
Gimenez, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) :705-717
[5]   Optical and acoustical observations of the effects of ultrasound on contrast agents [J].
Dayton, PA ;
Morgan, KE ;
Klibanov, AL ;
Brandenburger, GH ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (01) :220-232
[6]   ULTRASOUND SCATTERING PROPERTIES OF ALBUNEX MICROSPHERES [J].
DEJONG, N ;
HOFF, L .
ULTRASONICS, 1993, 31 (03) :175-181
[7]   ABSORPTION AND SCATTER OF ENCAPSULATED GAS FILLED MICROSPHERES - THEORETICAL CONSIDERATIONS AND SOME MEASUREMENTS [J].
DEJONG, N ;
HOFF, L ;
SKOTLAND, T ;
BOM, N .
ULTRASONICS, 1992, 30 (02) :95-103
[8]   In vivo targeting of acoustically reflective liposomes for intravascular and transvascular ultrasonic enhancement [J].
Demos, SM ;
Alkan-Onyuksel, H ;
Kane, BJ ;
Ramani, K ;
Nagaraj, A ;
Greene, R ;
Klegerman, M ;
McPherson, DD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (03) :867-875
[9]   Imaging and spectrum analysis of contrast agents in the in vivo rabbit eye using very-high-frequency ultrasound [J].
Deng, CX ;
Lizzi, FL ;
Silverman, RH ;
Ursea, R ;
Coleman, DJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (03) :383-394
[10]   Feasibility of mitral flow assessment by echo-contrast ultrasound, part I: Determination of the properties of echo-contrast agents [J].
Herman, B ;
Einav, S ;
Vered, Z .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (05) :787-795