Analytical performance of an axial ICP-TOFMS, in terms of accuracy, precision, resolution, signal stability, repeatability, reproducibility, precision of isotope ratios and detection limits is reported. Cool plasma conditions (low power and high central gas flow) allow the determination of K, Ca and Fe at trace levels. Detection limits for 64 elements are reported with typical values from 0.5-20 pg ml(-1) (3 s criterion). The long-term stability over 4 h for the raw signal ranges between 1.0% RSD for Li-7 to 2.1% RSD for Ca-40 operating under cool plasma conditions. Under normal plasma conditions the corresponding values are 6.9% RSD for Pb-208 to 12.8% RSD for Co-59. Accuracy for the determination of 16 different elements is assessed by measuring NIST 1643d (trace elements in water), yielding results in agreement with certified values. Results for isotopic ratio determinations demonstrate that a precision of 0.07-0.7% RSD is obtained within a short data acquisition period.
引用
收藏
页码:1807 / 1814
页数:8
相关论文
共 27 条
[2]  
*CRC INC, 1984, CHEM RUBB CO HDB CHE
[3]   PLASMA SOURCE-MASS SPECTROMETRY USING AN INDUCTIVELY COUPLED PLASMA AND A HIGH-RESOLUTION QUADRUPOLE MASS FILTER [J].
DATE, AR ;
GRAY, AL .
ANALYST, 1981, 106 (1269) :1255-1267
[4]   Quality assurance of arsenic, lead, tin and zinc in copper alloys using axial inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) [J].
Emteborg, H ;
Tian, XD ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (10) :1567-1572
[5]  
EVANS EH, 1995, INDUCTIVELY COUPLED, P35
[6]   EQUIPMENT STABILITY IN X-RAY-FLUORESCENCE SPECTROMETRY AND RADIOACTIVE COUNTING - STATISTICAL APPROACH [J].
HOOTON, KAH ;
PARSONS, ML .
ANALYTICAL CHEMISTRY, 1973, 45 (13) :2218-2227
[7]   INDUCTIVELY COUPLED ARGON PLASMA AS AN ION-SOURCE FOR MASS-SPECTROMETRIC DETERMINATION OF TRACE-ELEMENTS [J].
HOUK, RS ;
FASSEL, VA ;
FLESCH, GD ;
SVEC, HJ ;
GRAY, AL ;
TAYLOR, CE .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2283-2289
[8]  
Ingle J.D.J., SPECTROCHEMICAL ANAL
[9]   ALLEVIATION OF OVERLAP INTERFERENCES FOR DETERMINATION OF POTASSIUM ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
JIANG, SJ ;
HOUK, RS ;
STEVENS, MA .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1217-1221
[10]   DETERMINATION OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
LONGERICH, HP ;
FRYER, BJ ;
STRONG, DF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :39-48