A numerical study of blood flow in coronary artery bypass graft side-to-side anastomoses

被引:69
作者
Bonert, M
Myers, JG
Fremes, S
Williams, J
Ethier, CR
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 3G8, Canada
[3] Univ Toronto, Dept Surg, Toronto, ON M5S 3G8, Canada
[4] Univ Toronto, Sunnybrook Hlth Sci Ctr, Toronto, ON M5S 3G8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
side-to-side anastomosis; sequential grafts; ITA grafts; hemodynamics; coronary bypass grafting; numerical modeling;
D O I
10.1114/1.1481052
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Purpose: When sequential grafts are used in multivessel coronary artery bypass grafting, the graft first supplies blood to one or more coronary arteries via a side-to-side anastomosis. We studied hemodynamics in idealized models of "parallel" and "diamond" side-to-side anastomoses, identifying features that might promote restenosis. Methods: Blood flow was computed in three representative anastomosis configurations: parallel side-to-side, diamond side-to-side, and end-to-side. We compared configurations and the effect of host-graft diameter ratio. Results: Hemodynamic patterns depended strongly on anastomosis geometry and graft/host diameter ratio. In the distal graft, the diamond configuration had large areas of low wall shear stress (WSS) and high spatial WSS gradients. In the proximal graft the unfavorable WSS patterns were comparable for all models, while the distal portion of the host artery the diamond model was best. Models with smaller host arteries had smaller regions of low WSS. Conclusions: The parallel configuration was preferred over the diamond for maintaining graft patency, while the diamond configuration appeared best for maintaining host artery patency. Since graft patency is critical, parallel configurations seem hemodynamically advantageous. Larger graft/host ratios have better hemodynamic performance than smaller ones. (C) 2002 Biomedical Engineering Society.
引用
收藏
页码:599 / 611
页数:13
相关论文
共 39 条
[1]
BARTLEY TD, 1972, ARCH SURG-CHICAGO, V105, P915
[2]
ANASTOMOTIC INTIMAL HYPERPLASIA - MECHANICAL INJURY OR FLOW INDUCED [J].
BASSIOUNY, HS ;
WHITE, S ;
GLAGOV, S ;
CHOI, E ;
GIDDENS, DP ;
ZARINS, CK .
JOURNAL OF VASCULAR SURGERY, 1992, 15 (04) :708-717
[3]
BONERT M, 1999, CAN J CARDIOL, V15, pD160
[4]
Butany JW, 1998, CAN J CARDIOL, V14, P671
[5]
Sequential vein bypass grafting: tactics and long-term results [J].
Christenson, JT ;
Simonet, F ;
Schmuziger, M .
CARDIOVASCULAR SURGERY, 1998, 6 (04) :389-397
[6]
MR CHARACTERIZATION OF BLOOD-FLOW IN NATIVE AND GRAFTED INTERNAL MAMMARY ARTERIES [J].
DEBATIN, JF ;
STRONG, JA ;
SOSTMAN, HD ;
NEGROVILAR, R ;
PAINE, SS ;
DOUGLAS, JM ;
PELC, NJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (03) :443-450
[7]
DILLEY RJ, 1988, ARCH SURG-CHICAGO, V123, P691
[8]
Long-term clinical and angiographic follow-up of sequential internal thoracic artery grafting [J].
Dion, R ;
Glineur, D ;
Derouck, D ;
Verhelst, R ;
Noirhomme, P ;
El Khoury, G ;
Degrave, E ;
Hanet, C .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (04) :407-414
[9]
Steady flow separation patterns in a 45 degree junction [J].
Ethier, CR ;
Prakash, S ;
Steinman, DA ;
Leask, RL ;
Couch, GG ;
Ojha, M .
JOURNAL OF FLUID MECHANICS, 2000, 411 :1-38
[10]
Ethier CR, 1998, J BIOMECH, V31, P609, DOI 10.1016/S0021-9290(98)00059-1