Effective dose and energy imparted in diagnostic radiology

被引:63
作者
Huda, W
Gkanatsios, NA
机构
[1] Department of Radiology, University of Florida, Gainesville, FL 32610-0374
关键词
patient dosimetry; pediatric dosimetry; effective dose; energy imparted;
D O I
10.1118/1.598153
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The patient effective dose, E, is an indicator of the stochastic radiation risk associated with radiographic or fluoroscopic x-ray examinations. Determining effective doses far radiologic examinations by measurement or calculation is generally very difficult. By contrast, the energy imparted, epsilon, to the patient may be obtained from the x-ray exposure-area product incident on the patient. As energy imparted is approximately proportional to the effective dose for any given x-ray radiographic view, the availability of E/epsilon ratios for common radiographic projections provides a convenient way for estimating effective doses. Ratios of E/epsilon were obtained for 68 projections using E and epsilon values obtained from published dosimetry data computed using Monte Carlo techniques on an adult anthropomorphic phantom. The average E/epsilon ratio for the 68 projections in adults was 17.8 +/- 1.4 mSv/J, whereas uniform whole body irradiation corresponds to 14.1 mSv/J. The major determinant of E/epsilon ratios was the projection employed (the body region irradiated and x-ray beam orientation), whereas the tube potential and beam filtration were of secondary importance. Adult E/epsilon ratios may also be used to obtain effective doses to pediatric patients undergoing x-ray examinations by application of a correction factor based on the patient mass. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1311 / 1316
页数:6
相关论文
共 41 条
[1]   Simple methods for the estimation of dose distributions, organ doses and energy imparted in paediatric radiology [J].
Almen, A ;
Nilsson, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (07) :1093-1105
[2]  
Almen A., 1996, Journal of Radiological Protection, V16, P81, DOI 10.1088/0952-4746/16/2/004
[3]  
[Anonymous], 1991, NRPBSR262
[4]  
[Anonymous], 1991, Annals of the ICRP, V21
[5]  
[Anonymous], ANN ICRP
[6]   ENERGY IMPARTED TO THE PATIENT IN DIAGNOSTIC-RADIOLOGY - CALCULATION OF CONVERSION FACTORS FOR DETERMINING THE ENERGY IMPARTED FROM MEASUREMENTS OF THE AIR COLLISION KERMA INTEGRATED OVER BEAM AREA [J].
CARLSSON, GA ;
CARLSSON, CA ;
PERSLIDEN, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) :1329-1341
[7]   RESULTS OF A SURVEY OF DOSES TO PEDIATRIC-PATIENTS UNDERGOING COMMON RADIOLOGICAL EXAMINATIONS [J].
CHAPPLE, CL ;
FAULKNER, K ;
LEE, REJ ;
HUNTER, EW .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (771) :225-231
[8]   RADIATION-DOSES TO PEDIATRIC-PATIENTS UNDERGOING LESS COMMON RADIOLOGICAL PROCEDURES INVOLVING FLUOROSCOPY [J].
CHAPPLE, CL ;
FAULKNER, K ;
LEE, REJ ;
HUNTER, EW .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (789) :823-827
[9]   A PHANTOM BASED METHOD FOR DERIVING TYPICAL PATIENT DOSES FROM MEASUREMENTS OF DOSE-AREA PRODUCT ON POPULATIONS OF PATIENTS [J].
CHAPPLE, CL ;
BROADHEAD, DA ;
FAULKNER, K .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (814) :1083-1086
[10]   ENERGY IMPARTED TO NEONATES DURING X-RAY EXAMINATIONS IN A SPECIAL CARE BABY UNIT [J].
CHAPPLE, CL ;
FAULKNER, K ;
HUNTER, EW .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (796) :366-370