Sudden death after radiofrequency ablation of the atrioventricular node in patients with atrial fibrillation

被引:43
作者
Ozcan, C
Jahangir, A
Friedman, PA
Hayes, DL
Munger, TM
Rea, RF
Lloyd, MA
Packer, DL
Hodge, DO
Gersh, BJ
Hammill, SC
Shen, WK [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis & Internal Med, Rochester, MN 55905 USA
[2] Mayo Clin, Sect Biostat, Rochester, MN USA
关键词
D O I
10.1016/S0735-1097(02)01927-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We evaluated the incidence and predictors of sudden death after atrioventricular (AV) node ablation and pacemaker implantation. BACKGROUND Sudden death may occur after radiofrequency catheter ablation of the AV node and pacemaker implantation in patients with atrial fibrillation (AF). Whether it is related to the procedure or to pre-existing heart disease remains unclear. METHODS All patients who had radiofrequency catheter ablation of the AV node and pacemaker implantation for rate control of medically refractory AF were identified retrospectively and observed prospectively. All patients with sudden death after ablation were identified. The relationship between the procedure and sudden death was defined on the basis of the time between the two as "likely," "possibly" or "unlikely." RESULTS Of 334 consecutive patients with AF who under-went AV node ablation, nine had sudden death after the ablation. Four patients (1.2%) had sudden death likely related to the procedure: in 3 patients, arrest occurred within 48 h after the procedure; in one patient, arrest occurred four days after the procedure. In three other patients (0.9%), sudden death was possibly related to the procedure because the event occurred within three months afterward. The remaining two deaths were unrelated to the procedure. Diabetes, New York Heart Association functional class (greater than or equal toII), preprocedure ventricular arrhythmia, mitral or aortic stenosis, aortic regurgitation and chronic obstructive pulmonary disease were independent predictors for sudden death. CONCLUSIONS Sudden death likely or possibly related to catheter ablation occurred in 7 of 334 patients (2.1%). Risk of sudden death is highest within two days after the procedure. (C) 2002 by the American College of Cardiology Foundation.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 28 条
[21]   Management of patients with atrial fibrillation - A statement for healthcare professionals from the subcommittee on electrocardiography and electrophysiology, American Heart Association [J].
Prystowsky, EN ;
Benson, DW ;
Fuster, V ;
Hart, RG ;
Kay, GN ;
Myerburg, RJ ;
Naccarelli, GV ;
Wyse, DG .
CIRCULATION, 1996, 93 (06) :1262-1277
[22]   CATHETER-INDUCED ABLATION OF THE ATRIOVENTRICULAR JUNCTION TO CONTROL REFRACTORY SUPRA-VENTRICULAR ARRHYTHMIAS [J].
SCHEINMAN, MM ;
MORADY, F ;
HESS, DS ;
GONZALEZ, R .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1982, 248 (07) :851-855
[23]  
Touboul P, 1999, AM J CARDIOL, V83, p241D
[24]   CATHETER ABLATION OF THE ATRIOVENTRICULAR JUNCTION USING RADIOFREQUENCY ENERGY AND A BILATERAL CARDIAC APPROACH [J].
TROHMAN, RG ;
SIMMONS, TW ;
MOORE, SL ;
FIRSTENBERG, MS ;
WILLIAMS, D ;
MALONEY, JD .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (18) :1438-1443
[25]   EFFECTS ON CARDIAC-PERFORMANCE OF ATRIOVENTRICULAR NODE CATHETER ABLATION USING RADIOFREQUENCY CURRENT FOR DRUG-REFRACTORY ATRIAL ARRHYTHMIAS [J].
TWIDALE, N ;
SUTTON, K ;
BARTLETT, L ;
DOOLEY, A ;
WINSTANLEY, S ;
HEDDLE, W ;
HASSAM, R ;
KOUTSOUNIS, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (06) :1275-1284
[26]  
WALKER SH, 1967, BIOMETRIKA, V54, P167, DOI 10.2307/2333860
[27]   Clinical outcomes after ablation and pacing therapy for atrial fibrillation - A meta-analysis [J].
Wood, MA ;
Brown-Mahoney, C ;
Kay, GN ;
Ellenbogen, KA .
CIRCULATION, 2000, 101 (10) :1138-1144
[28]   Sudden death in dilated cardiomyopathy [J].
Wu, AH ;
Das, SK .
CLINICAL CARDIOLOGY, 1999, 22 (04) :267-272