Role of 11-C-methionine positron emission tomography for the delineation of the tumor volume in pharyngo-laryngeal squamous cell carcinoma: comparison with FDG-PET and CT

被引:58
作者
Geets, X
Daisne, JF
Gregoire, V
Hamoir, M
Lonneux, M
机构
[1] Univ Catholique Louvain, Sch Med, Clin Univ St Luc, Dept Nucl Med, B-1200 Brussels, Belgium
[2] Univ Catholique Louvain, Sch Med, Clin Univ St Luc, Dept Radiotherapy, B-1200 Brussels, Belgium
[3] Univ Catholique Louvain, Sch Med, Clin Univ St Luc, Dept Otorhinolaryngol, B-1200 Brussels, Belgium
关键词
11-C-methionine; 2-[18F] fluoro-2-deoxy-D-glucose; positron emission tomography; head and neck squamous cell carcinoma; tumor delineation;
D O I
10.1016/j.radonc.2004.02.013
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Although computed tomography (CT) remains the imaging modality of reference in head and neck squamous cell carcinoma (HNSCC) for the three-dimensional (3D) conformal radiotherapy, its poor soft tissue contrast can hamper precisely delineate the tumor volume. Besides anatomical imaging, 2-[18F] fluoro-2-deoxy-D-glucose-positron emission tomography (FDG-PET) has been shown to enhance the accuracy of the tumor delineation but L-methyl [11C]-methionine-positron emission tomography (MET-PET) has never been tested for this purpose. This study was undertaken to determine the potential added value of MET-PET for the delineation of gross target volume (GTV) in HNSCC, as compared to CT and FDG-PET. Patients and methods: Twenty-three patients (10 oropharynx, 8 larynx and 5 hypopharynx) presenting with stage II-IV HNSCC were prospectively enrolled. They were treated by primary radiotherapy or by total laryngectomy. Images (CT, FDG-PET and MET-PET) were acquired with a thermoplastic mask and after coregistration, tumor volumes were delineated on CT and using an adaptative threshold-based automatic method on FDG- and MET-PET. Absolute volumes as well as the mismatch between modalities were compared. Results: For oropharyngeal lesions, FDG volumes were significantly smaller (19.43 ml +/- 21.36) than CT (29.04 ml +/- 30.97) (P = 0.013). On the other hand, MET volumes (24.36 ml +/- 20.59) were not different from CT volumes. Similar results were found for laryngeal and hypopharyngeal tumors, with volume of 24.93 ml +/- 19.02 for CT, 21.84 ml +/- 15.32 for MET-PET and 14.49 ml +/- 11.3 for FDG-PET (P = 0.003). Large mismatches were observed between modalities, in particular between CT and PET. Conclusions: Our study confirms that the use of FDG-PET may result in a significant reduction of GTV's as compared to CT. On the contrary, MET-PET does not have any additional value since MET volumes are not different from CT volumes, probably because of the high uptake of MET by the normal mucosa and salivary glands surrounding the tumor. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:267 / 273
页数:7
相关论文
共 15 条
[1]   Head and neck cancer: Detection of recurrence with three-dimensional principal components analysis at dynamic FDG PET [J].
Anzai, Y ;
Minoshima, S ;
Wolf, GT ;
Wahl, RL .
RADIOLOGY, 1999, 212 (01) :285-290
[2]  
BEKER M, 1995, RADIOLOGY, V194, P661
[3]   Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT:: The impact of 18FDG-hybrid PET fusion [J].
Caldwell, CB ;
Mah, K ;
Ung, YC ;
Danjoux, CE ;
Balogh, JM ;
Ganguli, SN ;
Ehrlich, LE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :923-931
[4]  
Chesnay E, 2003, J NUCL MED, V44, P526
[5]   Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients:: accuracy, reproducibility and consistency [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Cosnard, G ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :237-245
[6]   Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios:: influence of reconstruction algorithms [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Doumont, T ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :247-250
[7]  
DAISNE JF, UNPUB RADIOLOGY
[8]   Laryngeal tumor volume measurements determined with CT: A study on intra- and interobserver variability [J].
Hermans, R ;
Feron, M ;
Bellon, E ;
Dupont, P ;
Van den Bogaert, W ;
Baert, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (03) :553-557
[9]  
KUBOTA R, 1995, J NUCL MED, V36, P484
[10]   IMAGING OF HEAD AND NECK TUMORS WITH POSITRON EMISSION TOMOGRAPHY AND [C-11] METHIONINE [J].
LESKINENKALLIO, S ;
LINDHOLM, P ;
LAPELA, M ;
JOENSUU, H ;
NORDMAN, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (05) :1195-1199