Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients:: accuracy, reproducibility and consistency

被引:114
作者
Daisne, JF
Sibomana, M
Bol, A
Cosnard, G
Lonneux, M
Grégoire, V
机构
[1] Catholic Univ Louvain, St Luc Univ Hosp, Dept Radiat Oncol, B-1200 Brussels, Belgium
[2] Catholic Univ Louvain, St Luc Univ Hosp, Dept Nucl Med, Positron Emiss Tomogr Unit, B-1200 Brussels, Belgium
[3] Catholic Univ Louvain, St Luc Univ Hosp, Dept Radiol, B-1200 Brussels, Belgium
关键词
coregistration; PET scan; CT scan; MRI; head and neck;
D O I
10.1016/j.radonc.2003.10.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: In radiotherapy planning of head and neck tumors, coregistration of various anatomical (e.g. CT and MRI) and functional (e.g. PET) images is a promising way to improve the delineation of the target volumes. In this paper, we report data on accuracy, reproducibility and consistency of an interactive coregistration procedure in a specifically designed phantom and in a group of patients with primary head and neck tumors. Patients and methods: A phantom and a group of four patients with pharyngo-laryngeal tumors were imaged by CT scan (taken as the reference image), MRI (T1- and T2-weighed sequences) and PET (transmission and FDG emission). Sets of images were coregistered using an interactive rigid coregistration method based on interactive surface segmentation. Translational and rotational displacements relative to the reference CT scan were measured and expressed in terms of accuracy, reproducibility (inter- and intra-observer variation) and consistency (between T1- and T2-weighed MRI). Results: Coregistration accuracy was in the range of 0.8-6.2 mm and 1.2-4.6 mm for the phantom and the patients, respectively. Accuracy was slightly worse in the z direction, and was significantly correlated with the spatial resolution of the imaging modalities, at least for the phantom. Inter- and intra-observer variations were very small and always far below the residual variance. Consistency was perfect except in the y direction. Conclusion: Providing adequate set-up is chosen, accurate coregistration of CT, MR and FDG-PET images can be obtained in the head and neck area. Coregistration was consistent and highly reproducible among observers. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 32 条
[1]   Clinical role of positron emission tomography in oncology [J].
Bomanji, J. B. ;
Costa, D. C. ;
Ell, P. J. .
LANCET ONCOLOGY, 2001, 2 (03) :157-164
[2]   CT and PET lung image registration and fusion in radiotherapy treatment planning using the chamfer-matching [J].
Cai, JL ;
Chu, JCH ;
Recine, D ;
Sharma, M ;
Nguyen, C ;
Rodebaugh, R ;
Saxena, VA ;
Ali, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (04) :883-891
[3]  
Chatziioannou AF, 1999, J NUCL MED, V40, P1164
[4]   Positron emission tomography imaging in oncology [J].
Delbeke, D ;
Martin, WH .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2001, 39 (05) :883-+
[5]   Design and evaluation of an LSO PET detector for breast cancer imaging [J].
Doshi, NK ;
Shao, YP ;
Silverman, RW ;
Cherry, SR .
MEDICAL PHYSICS, 2000, 27 (07) :1535-1543
[6]   New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Schaller, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07) :839-845
[7]   Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors [J].
Gilbeau, L ;
Octave-Prignot, M ;
Loncol, T ;
Renard, L ;
Scalliet, P ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) :155-162
[8]  
HAACKE EM, 1999, MAGNETIC RESONANCE I, P265
[9]   Registration and alignment of three-dimensional images: An interactive visual approach [J].
Habboush, IH ;
Mitchell, KD ;
Mulkern, RV ;
Barnes, PD ;
Treves, ST .
RADIOLOGY, 1996, 199 (02) :573-578
[10]   Algorithms for radiological image registration and their clinical application [J].
Hawkes, DJ .
JOURNAL OF ANATOMY, 1998, 193 :347-361