Diamond as a tool for synchrotron radiation monitoring:: beam position, profile, and temporal distribution

被引:36
作者
Bergonzo, P [1 ]
Brambilla, A
Tromson, D
Mer, C
Hordequin, C
Guizard, B
Foulon, F
Solé, VA
Gauthier, C
机构
[1] CEA Saclay, LETI, CEA, DEIN,SPE, F-91191 Gif Sur Yvette, France
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
beam monitoring; CVD diamond; synchrotron radiation; radiation detection; ultrafast; X-rays;
D O I
10.1016/S0925-9635(99)00206-X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Diamond polycrystalline films have been synthesised using the chemical vapour deposition technique in order to fabricate new types of photodetectors for the characterisation of X-ray light sources as encountered in synchrotron experiments. We present here new diamond-based devices for three different applications. including (i) semitransparent beam position monitors with high position resolution (< 2 mu m), (ii) beam profile monitors with 20 mu pitch resolution, and (iii) ultrafast diamond detectors for the 100 ps range that enable the intensity and temporal monitoring of fast X-ray pulses. These devices can be used for in-line characterisation of synchrotron beam line experiments as well as for synchrotron machine diagnostics. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:960 / 964
页数:5
相关论文
共 17 条
[1]   Diamond-based semi-transparent beam-position monitor for synchrotron radiation applications [J].
Bergonzo, P ;
Brambilla, A ;
Tromson, D ;
Marshall, RD ;
Jany, C ;
Foulon, F ;
Gauthier, C ;
Solé, VA ;
Rogalev, A ;
Goulon, J .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :1-5
[2]  
BERGONZO P, UNPUB
[3]  
BERGONZO P, 1999, UNPUB DIAM 99 M PRAG
[4]  
BRAMBILLA A, 1999, UNPUB IEEE T NUCL SC
[5]  
CUZIN M, 1993, MATER RES SOC S P, V302, P169
[6]   Neutron detectors made from chemically vapour deposited semiconductors [J].
Foulon, F ;
Bergonzo, P ;
Brambilla, A ;
Jany, C ;
Guizard, B ;
Marshall, RD .
SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 :591-596
[7]   CVD diamond detectors for radiation pulse characterisation [J].
Foulon, F ;
Bergonzo, P ;
Jany, C ;
Gicquel, A ;
Pochet, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :42-45
[8]   Comparison of various GaAs materials used for gamma-ray pulses characterisation [J].
Foulon, F ;
Brullot, B ;
Rubbelynck, C ;
Bergonzo, P ;
Pochet, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1372-1375
[9]   DEVELOPMENT OF DIAMOND RADIATION DETECTORS FOR SSC AND LHC [J].
FRANKLIN, M ;
FRY, A ;
GAN, KK ;
HAN, S ;
KAGAN, H ;
KANDA, S ;
KANIA, D ;
KASS, R ;
KIM, SK ;
MALCHOW, R ;
MORROW, F ;
OLSEN, S ;
PALMER, WF ;
PAN, LS ;
SANNES, F ;
SCHNETZER, S ;
STONE, R ;
SUGIMOTO, Y ;
THOMSON, GB ;
WHITE, C ;
ZHAO, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3) :39-42
[10]   MODULATED DETECTION OF MULTIBEAM DICHROISM USING PHOTODIODES [J].
GAUTHIER, C ;
GOUJON, G ;
FEITE, S ;
MOGUILINE, E ;
BRAICOVICH, L ;
BROOKES, NB ;
GOULON, J .
PHYSICA B, 1995, 208 (1-4) :232-234