Twenty new digital brain phantoms for creation of validation image data bases

被引:198
作者
Aubert-Broche, Berengere
Griffin, Mark
Pike, G. Bruce
Evans, Alan C.
Collins, D. Louis
机构
[1] McGill Univ, Montreal Neurol Inst, Brain Imaging Ctr, Montreal, PQ H3A 2B4, Canada
[2] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ H3A 2B4, Canada
关键词
brain; digital phantom; magnetic resonance imaging (MRI); simulation; validation;
D O I
10.1109/TMI.2006.883453
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Simulations provide a way of generating data where ground truth is known, enabling quantitative testing of image processing methods. In this paper, we present the construction of 20 realistic digital brain phantoms that can be used to simulate medical imaging data. The phantoms are made from 20 normal adults to take into account intersubject anatomical variabilities. Each digital brain phantom was created by registering and averaging four T1, T2, and proton density (PD)-weighted magnetic resonance imaging (MRI) scans from each subject. A fuzzy minimum distance classification was used to classify voxel intensities from T1, T2, and PD average volumes into grey-matter, white matter, cerebro-spinal fluid, and fat. Automatically generated mask volumes were required to separate brain from nonbrain structures and ten fuzzy tissue volumes were created: grey matter, white matter, cerebro-spinal fluid, skull, marrow within the bone, dura, fat, tissue around the fat, muscles, and skin/muscles. A fuzzy vessel class was also obtained from the segmentation of the magnetic resonance angiography scan of the subject. These eleven fuzzy volumes that describe the spatial distribution of anatomical tissues define the digital phantom, where voxel intensity is proportional to the fraction of tissue within the voxel. These fuzzy volumes can be used to drive simulators for different modalities including MRI, PET, or SPECT. These phantoms were used to construct 20 simulated T1-weighted MR scans. To evaluate the realism of these simulations, we propose two approaches to compare them to real data acquired with the same acquisition parameters. The first approach consists of comparing the intensities within the segmented classes in both real and simulated data. In the second approach, a whole brain voxel-wise comparison between simulations and real T1-weighted data is performed. The first comparison underlines that segmented classes appear to properly represent the anatomy on average, and that inside these classes, the simulated and real intensity values are quite similar. The second comparison enables the study of the regional variations with no a priori class. The experiments demonstrate that these variations are small when real data are corrected for intensity nommiformity.
引用
收藏
页码:1410 / 1416
页数:7
相关论文
共 20 条
[1]   Qualitative and quantitative evaluation of six algorithms for correcting intensity nonuniformity effects [J].
Arnold, JB ;
Liow, JS ;
Schaper, KA ;
Stern, JJ ;
Sled, JG ;
Shattuck, DW ;
Worth, AJ ;
Cohen, MS ;
Leahy, RM ;
Mazziotta, JC ;
Rottenberg, DA .
NEUROIMAGE, 2001, 13 (05) :931-943
[2]   Voxel-based morphometry - The methods [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2000, 11 (06) :805-821
[3]   A new improved version of the realistic digital brain phantom [J].
Aubert-Broche, Berengere ;
Evans, Alan C. ;
Collins, Louis .
NEUROIMAGE, 2006, 32 (01) :138-145
[4]   Reliability of tissue volumes and their spatial distribution for segmented magnetic resonance images [J].
Cardenas, VA ;
Ezekiel, F ;
Di Sclafani, V ;
Gomberg, B ;
Fein, G .
PSYCHIATRY RESEARCH-NEUROIMAGING, 2001, 106 (03) :193-205
[5]  
Cocosco CA, 2002, LECT NOTES COMPUT SC, V2488, P516
[6]   AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE [J].
COLLINS, DL ;
NEELIN, P ;
PETERS, TM ;
EVANS, AC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :192-205
[7]  
Descoteaux M, 2004, LECT NOTES COMPUT SC, V3216, P500
[8]  
EVANS AC, 1993, NUCLEAR SCIENCE SYMPOSIUM & MEDICAL IMAGING CONFERENCE, VOLS 1-3, P1813, DOI 10.1109/NSSMIC.1993.373602
[9]  
Frangi AF, 1998, LECT NOTES COMPUT SC, V1496, P130, DOI 10.1007/BFb0056195
[10]   Validation of partial tissue segmentation of single-channel magnetic resonance images of the brain [J].
Grabowski, TJ ;
Frank, RJ ;
Szumski, NR ;
Brown, CK ;
Damasio, H .
NEUROIMAGE, 2000, 12 (06) :640-656