Development of an optical sensor probe for the detection of dissolved carbon dioxide

被引:46
作者
Burke, Conor S. [1 ]
Markey, Adam [1 ]
Nooney, Robert I. [1 ]
Byme, Patrick [1 ]
McDonagh, Colette [1 ]
机构
[1] Dublin City Univ, Natl Ctr Sensor Res, Dublin 9, Ireland
关键词
optical sensor probe; dissolved carbon dioxide; flurosence; dual luminophore referencing;
D O I
10.1016/j.snb.2005.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A robust, low-cost optical probe for the detection of dissolved carbon dioxide has been developed. The design centres on the use of a custom-designed polymer optical element (POE), which obviates the need for optical fibres, thereby improving probe stability and rendering it more suitable for use outside a laboratory environment. The probe employs LED excitation of a luminescent sensor membrane and signal detection is provided by a silicon PIN photodiode. The phase-based sensing technique of dual luminophore referencing (DLR) was employed in conjunction with a poly(dimethylsiloxane) (PDMS) sensor membrane to yield the sensor response. The membrane was doped with the fluorescent indicator, hydroxypyrenetrisulfonic acid (HPTS) along with a reference luminophore in the form of silica microparticles, doped with the fluorescent ruthenium complex, Ru(dpP)(3)(2+). A limit of detection of approximately 7 mu M of dissolved CO2 was achieved, demonstrating the promising potential of this generic sensor probe configuration. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:288 / 294
页数:7
相关论文
共 19 条
[1]  
Dean J. A., 1998, LANGES HDB CHEM
[2]   High-stability non-invasive autoclavable naked optical CO2 sensor [J].
Ge, XD ;
Kostov, Y ;
Rao, G .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (07) :857-865
[3]   Optical sensor for seawater salinity [J].
Huber, C ;
Klimant, I ;
Krause, C ;
Werner, T ;
Mayr, T ;
Wolfbeis, OS .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (2-3) :196-202
[4]  
Liebsch G, 1999, ADV MATER, V11, P1296, DOI 10.1002/(SICI)1521-4095(199910)11:15<1296::AID-ADMA1296>3.0.CO
[5]  
2-B
[6]   Dye-doped organically modified silica glass for fluorescence based carbon dioxide gas detection [J].
Malins, C ;
MacCraith, BD .
ANALYST, 1998, 123 (11) :2373-2376
[7]   Phase fluorometric dissolved oxygen sensor [J].
McDonagh, C ;
Kolle, C ;
McEvoy, AK ;
Dowling, DL ;
Cafolla, AA ;
Cullen, SJ ;
MacCraith, BD .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 74 (1-3) :124-130
[8]   COLORIMETRIC POLYMER FILM SENSORS FOR DISSOLVED CARBON-DIOXIDE [J].
MILLS, A ;
CHANG, Q .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 21 (02) :83-89
[9]   FLUORESCENCE PLASTIC THIN-FILM SENSOR FOR CARBON-DIOXIDE [J].
MILLS, A ;
CHANG, Q .
ANALYST, 1993, 118 (07) :839-843
[10]   Breath-by-breath measurement of carbon dioxide using a plastic film optical sensor [J].
Mills, A ;
Lepre, A ;
Wild, L .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 39 (1-3) :419-425