Accuracy of home blood glucose meters during hypoglycemia

被引:68
作者
Trajanoski, Z
Brunner, GA
Gfrerer, RJ
Wach, P
Pieber, TR
机构
[1] LUDWIG BOLTZMANN INST TECH LEBENSHILFEN, GRAZ, AUSTRIA
[2] KARL FRANZENS UNIV GRAZ, DEPT INTERNAL MED, GRAZ, AUSTRIA
关键词
D O I
10.2337/diacare.19.12.1412
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To evaluate the accuracy of home blood glucose meters during hypoglycemia. METHODS - Six blood glucose meter-One Touch II (LifeScan, Milpitas, CA), Companion II (Medisense, Cambridge, U.K.), Reflolux (Boehringer Mannheim, Mannheim, Germany), Accutrend (Boehringer Mannheim), Elite (Bayer, Munich, Germany), and HemoCue (HemoCue, Angelholm, Sweden)-were compared with a reference method (Beekman Glucose Analyzer 2). Glucose concentrations from arterialized venous blood samples were measured using all glucose meters (whole blood) and the reference method (plasma) during hypoglycemic-hyperinsulinemic clamps in 15 subjects. RESULTS - In total, 663 Mood glucose monitor readings and 119 reference values ranging from 2,28 to 3.89 mmol/l were analyzed. The correlation coefficients and the percentage of measurements within 20% and outside 40% of the reference values for each glucose meter were as follows: One Touch II: 0.91, 99.2% and 0%; Companion II: 0.81, 88.2%, and 2.5%; Reflolux: 0.78, 85.0% and 0.9%; Accutrend: 0.88, 46.0% and 6.6%; Elite: 0.78, 75.6% and 4.2%; and HemoCue: 0.93, 96.6% and 0% (P < 0.001). CONCLUSIONS - There were substantial differences between the blood glucose meters during hypoglycemia, and none of the devices met the latest criteria recommended by the American Diabetes Association.
引用
收藏
页码:1412 / 1415
页数:4
相关论文
共 16 条
  • [1] *AM DIAB ASS, 1987, DIABETES CARE, V10, P93
  • [2] ASHWORTH L, 1992, CLIN CHEM, V38, P1479
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] BOLLI GB, 1995, INT TXB DIABETES MEL, P1131
  • [5] EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE
    CLARKE, WL
    COX, D
    GONDERFREDERICK, LA
    CARTER, W
    POHL, SL
    [J]. DIABETES CARE, 1987, 10 (05) : 622 - 628
  • [6] COMPARISON OF 5 GLUCOSE METERS FOR SELF-MONITORING OF BLOOD-GLUCOSE BY DIABETIC-PATIENTS
    GIFFORDJORGENSEN, RA
    BORCHERT, J
    HASSANEIN, R
    TILZER, L
    EAKS, GA
    MOORE, WV
    [J]. DIABETES CARE, 1986, 9 (01) : 70 - 76
  • [7] ARTERIAL, ARTERIALIZED VENOUS, VENOUS AND CAPILLARY BLOOD-GLUCOSE MEASUREMENTS IN NORMAL MAN DURING HYPERINSULINEMIC EUGLYCEMIA AND HYPOGLYCEMIA
    LIU, D
    MOBERG, E
    KOLLIND, M
    LINS, PE
    ADAMSON, U
    MACDONALD, IA
    [J]. DIABETOLOGIA, 1992, 35 (03) : 287 - 290
  • [8] HOW ACCURATE ARE HOME BLOOD-GLUCOSE METERS WITH SPECIAL RESPECT TO THE LOW GLYCEMIC RANGE
    MOBERG, E
    LUNDBLAD, S
    LINS, PE
    ADAMSON, U
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 1993, 19 (03) : 239 - 243
  • [9] MOBERG E, 1994, THESIS KAROLINSKA I
  • [10] MOLITCH ME, 1994, DIABETES CARE, V17, P81