Reference ranges for tissue Doppler measures of maternal systolic and diastolic left ventricular function

被引:52
作者
Bamfo, J. E. A. K.
Kametas, N. A.
Nicolaides, K. H.
Chambers, J. B.
机构
[1] Univ London Kings Coll Hosp, Harris Birthright Res Ctr Fetal Med, London SE5 9RS, England
[2] Guys Hosp, Ctr Cardiothorac, London SE1 9RT, England
[3] St Thomas Hosp, London, England
关键词
Doppler echocardiography; maternal cardiac function; tissue Doppler imaging;
D O I
10.1002/uog.3966
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives Tissue Doppler imaging (TDI) is an echocardiographic technique that evaluates longitudinal myocardial tissue velocities during left ventricular systolic and diastolic function, relatively independently of loading conditions. Limited data are available regarding maternal cardiac function using TDI. The aim of this study was to construct reference charts for TDI indices in normal pregnancy. Methods This was a cross-sectional study on 104 pregnant women at 11-38 weeks of gestation and 19 non-pregnant controls. Doppler echocardiography was used to assess transmitral inflow velocities during diastole (peak velocity of early (E) and late (A) atrial filling), whilst TDI at the septal and lateral margins of the mitral annulus measured diastolic velocities (peak velocity of early (E') and late (A') diastolic filling) and peak systolic velocity (S'). The left ventricular filling index (E: E' ratio) was derived. The Tei index (ratio of isovolumetric time to ejection time) was measured. Results Systolic function assessed by TDI S' velocity was unaltered at the septal and lateral margins, although S' velocity at the lateral margin was higher (12%, P = 0.028) in the first two trimesters, compared to nonpregnant controls. Diastolic function was modified as demonstrated by an increase in A velocity (P = 0.01). Consequently, E : A decreased with gestation (P = 0.024). Similarly, A' increased at the septal and lateral margins (P < 0.001 and P = 0.02, respectively), resulting in a decrease in E' : A' ratios at the septal and lateral mitral margins (P = 0.001 and P = 0.001, respectively). E : E' at both mitral margins and Tei index were unaltered. Conclusion This study gives normal ranges for TDI indices in pregnancy. TDI demonstrated modified longitudinal systolic and diastolic function. Future studies will evaluate the potential of this technique in pregnancies complicated by hypertension and cardiac disease. Copyright (c) 2007 ISUOG. Published by John Whey & Sons, Ltd.
引用
收藏
页码:414 / 420
页数:7
相关论文
共 34 条
[21]   Relations of longitudinal left ventricular systolic function to left ventricular mass, load, and Doppler stroke volume [J].
Palmieri, Vittorio ;
Russo, Cesare ;
Arezzi, Emma ;
Pezzullo, Salvatore ;
Sabatella, Maria ;
Minichiello, Stefana ;
Celentano, Aldo .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (05) :348-355
[22]   RECOMMENDATIONS ON BLOOD-PRESSURE MEASUREMENT [J].
PETRIE, JC ;
OBRIEN, ET ;
LITTLER, WA ;
DESWIET, M .
BRITISH MEDICAL JOURNAL, 1986, 293 (6547) :611-615
[23]   Serial assessment of the cardiovascular system in normal pregnancy - Role of arterial compliance and pulsatile arterial load [J].
Poppas, A ;
Shroff, SG ;
Korcarz, CE ;
Hibbard, JU ;
Berger, DS ;
Lindheimer, MD ;
Lang, RM .
CIRCULATION, 1997, 95 (10) :2407-2415
[24]   Recommendations for quantification of Doppler echocardiography:: A report from the Doppler quantification task force of the nomenclature and standards committee of the American Society of Echocardiography [J].
Quiñones, MA ;
Otto, CM ;
Stoddard, M ;
Waggoner, A ;
Zoghbi, WA .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (02) :167-184
[25]   COMBINED DOPPLER AND ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT - THEORY AND APPLICATION IN PREGNANCY [J].
ROBSON, SC ;
DUNLOP, W ;
MOORE, M ;
HUNTER, S .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (11) :1014-1027
[26]   SERIAL STUDY OF FACTORS INFLUENCING CHANGES IN CARDIAC-OUTPUT DURING HUMAN-PREGNANCY [J].
ROBSON, SC ;
HUNTER, S ;
BOYS, RJ ;
DUNLOP, W .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (04) :H1060-H1065
[27]   Usefulness of isovolumic and systolic ejection signals by tissue Doppler for the assessment of left ventricular systolic function in ischemic or idiopathic dilated cardiomyopathy [J].
Ruan, QY ;
Nagueh, SF .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (06) :872-875
[28]   RECOMMENDATIONS REGARDING QUANTITATION IN M-MODE ECHOCARDIOGRAPHY - RESULTS OF A SURVEY OF ECHOCARDIOGRAPHIC MEASUREMENTS [J].
SAHN, DJ ;
DEMARIA, A ;
KISSLO, J ;
WEYMAN, A .
CIRCULATION, 1978, 58 (06) :1072-1083
[29]  
Tei C, 1995, J Cardiol, V26, P357
[30]   Doppler index combining systolic and diastolic myocardial performance: Clinical value in cardiac amyloidosis [J].
Tei, CW ;
Dujardin, KS ;
Hodge, DO ;
Kyle, RA ;
Tajik, AJ ;
Seward, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (03) :658-664