Extension of receiver operating characteristic analysis to data concerning multiple signal detection tasks

被引:7
作者
HajianTilaki, KO
Hanley, JA
Joseph, L
Collet, JP
机构
[1] MCGILL UNIV,DEPT EPIDEMIOL & BIOSTAT,MONTREAL,PQ H3A 1A2,CANADA
[2] ROYAL VICTORIA HOSP,DIV CLIN EPIDEMIOL,MONTREAL,PQ H3A 1A1,CANADA
[3] MONTREAL GEN HOSP,DIV CLIN EPIDEMIOL,MONTREAL,PQ H3G 1A4,CANADA
[4] MCGILL UNIV,JEWISH GEN HOSP,DIV CLIN EPIDEMIOL,MONTREAL,PQ H3T 1E2,CANADA
基金
加拿大自然科学与工程研究理事会;
关键词
data analysis; receiver operating characteristic curve (ROC); multiple signal detection tasks; jackknife;
D O I
10.1016/S1076-6332(05)80295-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. When receiver operating characteristic (ROC) studies involve multiple detection tasks in the same patient, the correlations among the within-patient interpretations and the shortage of patients raise several analytic challenges. The authors propose methods for both parametric and nonparametric analysis of this type of data. Methods. First, they computed one accuracy statistic for each task. Then, one jackknife ''pseudovalue'' was calculated for each task and each patient. Then, they formed a summary index from the accuracy statistics and calculated the standard error of this summary index on the basis of the observed correlations among the jackknife pseudovalues. The method was extended to comparisons of two diagnostic systems and illustrated by using data from a clinical study. Results and Conclusion. This approach can be used with rating or quantitative data and with any index of accuracy, whether calculated parametrically or nonparametrically.
引用
收藏
页码:222 / 229
页数:8
相关论文
共 14 条
  • [1] MULTICENTER TRIAL TO EVALUATE VASCULAR MAGNETIC-RESONANCE ANGIOGRAPHY OF THE LOWER-EXTREMITY
    BAUM, RA
    RUTTER, CM
    SUNSHINE, JH
    BLEBEA, JS
    BLEBEA, J
    CARPENTER, JP
    DICKEY, KW
    QUINN, SF
    GOMES, AS
    GRIST, TM
    MCNEIL, BJ
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (11): : 875 - 880
  • [2] HIGH-RESOLUTION, MAGNETIZATION-TRANSFER SATURATION, VARIABLE FLIP ANGLE, TIME-OF-FLIGHT MRA IN THE DETECTION OF INTRACRANIAL VASCULAR STENOSES
    DAGIRMANJIAN, A
    ROSS, JS
    OBUCHOWSKI, N
    LEWIN, JS
    TKACH, JA
    RUGGIERI, PM
    MASARYK, TJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (05) : 700 - 706
  • [3] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845
  • [4] DORIMAN DD, 1992, INVEST RADIOL, V27, P723
  • [5] Sampling variability of nonparametric estimates of the areas under receiver operating characteristic curves: An update
    Hanley, JA
    HajianTilaki, KO
    [J]. ACADEMIC RADIOLOGY, 1997, 4 (01) : 49 - 58
  • [6] A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1983, 148 (03) : 839 - 843
  • [7] THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1982, 143 (01) : 29 - 36
  • [8] Diagnostic accuracy of technologies used in low back pain assessment - Thermography, triaxial dynamometry, spinoscopy, and clinical examination
    Leclaire, R
    Esdaile, JM
    Jequier, JC
    Hanley, JA
    Rossignol, M
    Bourdouxhe, M
    [J]. SPINE, 1996, 21 (11) : 1325 - 1330
  • [9] STATISTICAL APPROACHES TO THE ANALYSIS OF RECEIVER OPERATING CHARACTERISTIC (ROC) CURVES
    MCNEIL, BJ
    HANLEY, JA
    [J]. MEDICAL DECISION MAKING, 1984, 4 (02) : 137 - 150
  • [10] Metz C.Z., 1984, INFORMATION PROCESSI, P432