HIGH-RESOLUTION, MAGNETIZATION-TRANSFER SATURATION, VARIABLE FLIP ANGLE, TIME-OF-FLIGHT MRA IN THE DETECTION OF INTRACRANIAL VASCULAR STENOSES

被引:51
作者
DAGIRMANJIAN, A [1 ]
ROSS, JS [1 ]
OBUCHOWSKI, N [1 ]
LEWIN, JS [1 ]
TKACH, JA [1 ]
RUGGIERI, PM [1 ]
MASARYK, TJ [1 ]
机构
[1] CASE WESTERN RESERVE UNIV HOSP,DEPT RADIOL,CLEVELAND,OH 44106
关键词
MAGNETIC RESONANCE IMAGING; TECHNIQUES; ANGIOGRAPHY; (MRA); BRAIN; BLOOD FLOW MAGNETIZATION TRANSFER;
D O I
10.1097/00004728-199509000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Factors that restrict 3D TOF MRA are limited resolution, saturation of flow, and degree of background suppression. We evaluated MRA for intracranial stenoses by using a 3D TOF technique that minimizes these factors. Materials and Methods: Twenty-nine patients underwent MRA and intraarterial digital subtraction angiography (DSA). The MRA studies were performed on a 1.5 T Siemens SP 4000 system. Integrated techniques applied to the conventional 3D TOF acquisition included the following: (a) 256 x 256 matrix with a 140 mm FOV and 0.9 mm slice thickness, yielding a 0.54 x 0.54 x 0.9 mm(3) voxel; (b) tilted optimized nonsaturating excitation (TONE); and (c) magnetization transfer saturation (MTS). The intraarterial DSA was performed on a Siemens Angiostar system with a 1,024 x 1,024 noninterpolated matrix. The MRAs were reviewed by two neuroradiologists. Two hundred seventy-seven vessels were evaluated for a total of 806 segments. Vessel segments were evaluated with a 5 point scale. Results: The estimated accuracy of MRA for detecting stenosis over all intracranial vessel segments was 0.88 +/- 0.03 and 0.89 +/- 0.02 for the two readers, respectively. The estimated accuracy ranged from 0.94 +/- 0.02 and 0.93 +/- 0.02 for detecting internal carotid artery stenosis by the two readers, respectively, to 0.65 +/- 0.17 and 0.71 +/- 0.15 for detecting distal vertebral artery stenosis. In vessels determined by catheter angiography to be stenosis-free, reader confidence at the proximal versus distal segments was similar for the internal carotid, basilar, and posterior cerebral arteries. However, for the anterior and middle cerebral arteries, one or both readers were more confident in diagnosing the proximal segment. Conclusion: High resolution MTS TONE 3D TOF MRA is an accurate technique for the screening of medium and large vessel intracranial stenoses.
引用
收藏
页码:700 / 706
页数:7
相关论文
共 16 条
  • [1] BALABAN R S, 1992, Magnetic Resonance Quarterly, V8, P116
  • [2] IMPROVED TIME-OF-FLIGHT MR ANGIOGRAPHY OF THE BRAIN WITH MAGNETIZATION TRANSFER CONTRAST
    EDELMAN, RR
    AHN, SS
    CHIEN, D
    WEI, L
    GOLDMANN, A
    MANTELLO, M
    KRAMER, J
    KLEEFIELD, J
    [J]. RADIOLOGY, 1992, 184 (02) : 395 - 399
  • [3] Efron B, 1982, JACKKNIFE BOOTSTRAP
  • [4] INTRACRANIAL VASCULAR STENOSIS AND OCCLUSION - EVALUATION WITH 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    HEISERMAN, JE
    DRAYER, BP
    KELLER, PJ
    FRAM, EK
    [J]. RADIOLOGY, 1992, 185 (03) : 667 - 673
  • [5] CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    HEISERMAN, JE
    DRAYER, BP
    FRAM, EK
    KELLER, PJ
    BIRD, CR
    HODAK, JA
    FLOM, RA
    [J]. RADIOLOGY, 1992, 182 (03) : 761 - 768
  • [6] CAROTID-ARTERY - PROSPECTIVE BLINDED COMPARISON OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY AND DUPLEX US
    HUSTON, J
    LEWIS, BD
    WIEBERS, DO
    MEYER, FB
    RIEDERER, SJ
    WEAVER, AL
    [J]. RADIOLOGY, 1993, 186 (02) : 339 - 344
  • [7] LASTER RE, 1993, AM J NEURORADIOL, V14, P681
  • [8] INTRACRANIAL CIRCULATION - PRELIMINARY CLINICAL-RESULTS WITH 3-DIMENSIONAL (VOLUME) MR ANGIOGRAPHY
    MASARYK, TJ
    MODIC, MT
    ROSS, JS
    RUGGIERI, PM
    LAUB, GA
    LENZ, GW
    HAACKE, EM
    SELMAN, WR
    WIZNITZER, M
    HARIK, SI
    [J]. RADIOLOGY, 1989, 171 (03) : 793 - 799
  • [9] 3-DIMENSIONAL (VOLUME) GRADIENT-ECHO IMAGING OF THE CAROTID BIFURCATION - PRELIMINARY CLINICAL-EXPERIENCE
    MASARYK, TJ
    MODIC, MT
    RUGGIERI, PM
    ROSS, JS
    LAUB, G
    LENZ, GW
    TKACH, JA
    HAACKE, EM
    SELMAN, WR
    HARIK, SI
    [J]. RADIOLOGY, 1989, 171 (03) : 801 - 806
  • [10] MATTLE HP, 1991, J VASC SURG, V13, P838