Clearance of iron oxide particles in rat liver - Effect of hydrated particle size and coating material on liver metabolism

被引:74
作者
Briley-Saebo, Karen C.
Johansson, Lars O.
Hustvedt, Svein Olaf
Haldorsen, Anita G.
Bjornerud, Atle
Fayad, Zahi A.
Ahlstrom, Haakan K.
机构
[1] CUNY Mt Sinai Sch Med, Imaging Sci Labs, New York, NY 10029 USA
[2] CUNY Mt Sinai Sch Med, Zena & Michael A Wiener Cardiovasc Inst, Marie Josee & Henry R Kravis Cardiovasc Hlth Ctr, New York, NY 10029 USA
[3] CUNY Mt Sinai Sch Med, Dept Med, New York, NY 10029 USA
[4] Univ Uppsala Hosp, Dept Diagnost Radiol, Uppsala, Sweden
[5] GE Hlth Care, Oslo, Norway
[6] Aker Univ Hosp, Rikshosp, Dept Radiol, Oslo, Norway
关键词
iron oxide particles; liver; MRI;
D O I
10.1097/01.rli.0000221321.90261.09
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: We sought to evaluate the effect of the particle size and coating material of various iron oxide preparations on the rate of rat liver clearance. Materials and Methods: The following iron oxide formulations were used in this study: dextran-coated ferumoxide (size = 97 nm) and ferumoxtran-10 (size = 21 nm), carboxydextran-coated SHU555A (size = 69 nm) and fractionated SHU555A (size = 12 nm), and oxidized-starch coated materials either unformulated NC100150 (size = 15 nm) or formulated NC100150 injection (size = 12 nm). All formulations were administered to 165 rats at 2 dose levels. Quantitative liver R-2* values were obtained during a 63-day time period. The concentration of iron oxide particles in the liver was determined by relaxometry, and these values were used to calculate the particle half-lives in the liver. Results: After the administration of a high dose of iron oxide, the half-life of iron oxide particles in rat liver was 8 days for dextran-coated materials, 10 days for carboxydextran materials, 14 days for unformulated oxidized-starch, and 29 days for formulated oxidized-starch. Conclusions: The results of the study indicate that materials with similar coating but different sizes exhibited similar rates of liver clearance. It was, therefore, concluded that the coating material significantly influences the rate of iron oxide clearance in rat liver.
引用
收藏
页码:560 / 571
页数:12
相关论文
共 62 条
[61]   THEORY OF NMR SIGNAL BEHAVIOR IN MAGNETICALLY INHOMOGENEOUS TISSUES - THE STATIC DEPHASING REGIME [J].
YABLONSKIY, DA ;
HAACKE, EM .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (06) :749-763
[62]   Differential uptake of ferumoxtran-10 and ferumoxytol, ultrasmall superparamagnetic iron oxide contrast agents in rabbit: Critical determinants of atherosclerotic plaque labeling [J].
Yancy, AD ;
Olzinski, AR ;
Hu, TCC ;
Lenhard, SC ;
Aravindhan, K ;
Gruver, SM ;
Jacobs, PM ;
Willette, RN ;
Jucker, BM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :432-442