Sol-gel-derived amperometric biosensor for hydrogen peroxide based on methylene green incorporated in Nafion film

被引:153
作者
Wang, BQ
Dong, SJ
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Electroanalyt Chem Lab, Changchun 130022, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Appl Chem, Natl Anal & Res Ctr Electrochem & Spect, Changchun 130022, Peoples R China
基金
中国国家自然科学基金;
关键词
sol-gel; amperometric biosensor; Nafion; methylene green; horseradish peroxidase;
D O I
10.1016/S0039-9140(99)00315-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hydrogen peroxide biosensor was fabricated by coating a sol-gel-peroxidase layer onto a Nafion-methylene green modified electrode. Immobilization of methylene green (MG) was attributed to the electrostatic force between MG(+) and the negatively charged sulfonic acid groups in Nafion polymer, whereas immobilization of horseradish peroxidase was attributed to the encapsulation function of the silica sol-gel network. Cyclic voltammetry and chronoamperometry were employed to demonstrate the feasibility of electron transfer between sol-gel-immobilized peroxidase and a glassy carbon electrode. Performance of the sensor was evaluated with respect to response time, sensitivity as well as operational stability. The enzyme electrode has a sensitivity of 13.5 mu A mM(-1) with a detection limit of 1.0 x 10(-7) M H2O2, and the sensor achieved 95% of the steady-state current within 20 s. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:565 / 572
页数:8
相关论文
共 37 条
[1]   Electrochemical behavior of methyl viologen at graphite electrodes modified with Nafion sol-gel composite [J].
Barroso-Fernandez, B ;
Lee-Alvarez, MT ;
Seliskar, CJ ;
Heineman, WR .
ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) :221-230
[2]   TTF-MODIFIED BIOSENSORS FOR HYDROGEN-PEROXIDE [J].
BIFULCO, L ;
CAMMAROTO, C ;
NEWMAN, JD ;
TURNER, APF .
ANALYTICAL LETTERS, 1994, 27 (08) :1443-1452
[3]   Stability of oxidases immobilized in silica gels [J].
Chen, Q ;
Kenausis, GL ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (19) :4582-4585
[4]   ELECTROCATALYTIC OXIDATION OF REDUCED NICOTINAMIDE COENZYMES AT METHYLENE GREEN-MODIFIED ELECTRODES AND FABRICATION OF AMPEROMETRIC ALCOHOL BIOSENSORS [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1994, 285 (1-2) :125-133
[5]   SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS [J].
DAVE, BC ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :A1120-A1127
[6]   FTIR STUDIES OF GEL TO GLASS CONVERSION IN TEOS FUMED SILICA-DERIVED GELS [J].
DE, G ;
KUNDU, D ;
KARMAKAR, B ;
GANGULI, D .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1993, 155 (03) :253-258
[8]   Encapsulation of biologicals within silicate, siloxane, and hybrid sol-gel polymers: An efficient and generic approach [J].
Gill, I ;
Ballesteros, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (34) :8587-8598
[9]   AN ELECTROCHEMICAL SENSOR FOR HYDROGEN-PEROXIDE BASED ON PEROXIDASE ADSORBED ON A SPECTROGRAPHIC GRAPHITE ELECTRODE [J].
JONSSON, G ;
GORTON, L .
ELECTROANALYSIS, 1989, 1 (05) :465-468
[10]   ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER [J].
KAMIN, RA ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1198-1205