Prediction of water-holding capacity and composition of porcine meat by comparative spectroscopy

被引:255
作者
Brondum, J
Munck, L
Henckel, P
Karlsson, A
Tornberg, E
Engelsen, SB
机构
[1] Royal Vet & Agr Univ, DK-1958 Frederiksberg, Denmark
[2] SFK Technol, DK-2730 Herlev, Denmark
[3] Res Ctr Foulum, Danish Inst Agr Sci, Dept Anim Prod Qual, DK-8830 Tjele, Denmark
[4] Lund Univ, Dept Food Engn, SE-22100 Lund, Sweden
关键词
chemometrics; fluorescence VIS; NIR; NMR; porcine meat; WHC;
D O I
10.1016/S0309-1740(99)00141-2
中图分类号
TS2 [食品工业];
学科分类号
0832 [食品科学与工程];
摘要
Four spectroscopic instruments, a fibre optical probe (FOP), a Visual (VIS) and near infrared (NIR) reflectance spectrophotometer, a reflectance spectrofluorometer and a low-field H-1 nuclear magnetic resonance (LF-NMR) instrument were used to perform measurements on two muscles (longissimus dorsi and semitendinosous) from 39 pigs, 18 of which were carriers of the Halothane gene. Water-holding capacity (drip loss and filter paper wetness) and chemical composition (intramuscular fat and water) of the muscle samples were determined for spectroscopic calibration. Prediction models were established by partial least squares regression to evaluate the potential of using the spectroscopic techniques in an on-line slaughterhouse system. VIS data gave good prediction models, indicating that current industrial colour systems can be advanced into more specific meat evaluation systems by including the entire visible spectral range. The FOP and fluorescence measurements were less successful, and suffered from sampling problems since they measure only a small area. The best regression models were obtained from LF-NMR data for all reference quality measures and yielded a correlation coefficient of 0.75 with drip loss. LF-NMR proved able to distinguish between the two muscles and the results for their longitudinal relaxation times, T-21, were proportional to their average myofibrillar cross-sectional areas reported in the literature. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 31 条
[1]
ANDERSEN JR, 1995, P ECCAMST M ROSK DEN
[2]
Comparative chemometric analysis of transverse low-field 1H NMR relaxation data [J].
Bechmann, IE ;
Pedersen, HT ;
Norgaard, L ;
Engelsen, SB .
ADVANCES IN MAGNETIC RESONANCE IN FOOD SCIENCE, 1999, (231) :217-225
[3]
BORGGAARD C, 1989, P INT C MEAT SCI TEC, V35, P212
[4]
ON THE WATER CONDITION IN PORK MEAT [J].
BORISOVA, MA ;
ORESHKIN, EF .
MEAT SCIENCE, 1992, 31 (03) :257-265
[5]
EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[6]
METABOLIC RESPONSE TO HALOTHANE IN PIGLETS SUSCEPTIBLE TO MALIGNANT HYPERTHERMIA - AN IN-VIVO P-31-NMR STUDY [J].
DECANNIERE, C ;
VANHECKE, P ;
VANSTAPEL, F ;
VILLE, H ;
GEERS, R .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (02) :955-962
[7]
WATER DISTRIBUTION IN PORCINE M-LONGISSIMUS DORSI IN RELATION TO SENSORY PROPERTIES [J].
FJELKNERMODIG, S ;
TORNBERG, E .
MEAT SCIENCE, 1986, 17 (03) :213-231
[8]
Forrest J. C., 1997, NPPC PORK QUAL SUMM, P79
[9]
ONLINE METHODS FOR PORK QUALITY DETECTION [J].
GARRIDO, MD ;
PEDAUYE, J ;
BANON, S ;
LOPEZ, MB ;
LAENCINA, J .
FOOD CONTROL, 1995, 6 (02) :111-113
[10]
Honikel K. O., 1987, Evaluation and control of meat quality in pigs. A seminar in the CEC Agricultural Research Programme, held in Dublin, Ireland, 21-22 November 1985., P129