Comparison of the iron oxide-based blood-pool contrast medium VSOP-C184 with gadopentetate dimeglumine for first-pass magnetic resonance angiography of the aorta and renal arteries in pigs

被引:40
作者
Schnorr, A
Wagner, S
Abramjuk, C
Wojner, I
Schink, T
Kroencke, TJ
Schellenberger, E
Hamm, B
Pilgrimm, H
Taupitz, M
机构
[1] Charite Univ Med Berlin, Inst Radiol, Dept Radiol, D-10098 Berlin, Germany
[2] Ferropharm GmbH, Forschungslabor, Teltow, Germany
[3] Charite Univ Med Berlin, Dept Med Biometry, Berlin, Germany
关键词
magnetic resonance imaging; contrast media; experimental studies; iron oxide particles; vascular imaging;
D O I
10.1097/01.rli.0000133944.30119.cc
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: VSOP-C184 at a dose of 0.045 mmol Fe/kg has been shown to be an efficient blood pool contrast medium for equilibrium magnetic resonance angiography (MRA) that can be administered as a bolus. The present study was performed to determine whether VSCP-C184 is also suitable for first-pass MRA. Materials and Methods: Fifteen MRA examinations at 1.5 T were performed in minipigs using a fast 3D fast low-angle shot (FLASH) sequence (repetition time = 4.5 ms, echo time = 1.7 ms, excitation angle = 25degrees, matrix 256, body phased-array coil). The citrate-stabilized iron oxide preparation VSOP-C184 was investigated (total particle diameter: 7.0 +/- 0.15 nm; core size: 4 nm) and compared with gadopentetate dimeglumine (Gd-DTPA). The following doses were tested: VSOP-C184: 0.015, 0.025, and 0.035 mmol Fe/kg,Gd-DTPA: 0.1 and 0.2 mmol Gd/kg; n = 3 examinations/dose. Data were analyzed quantitatively (signal enhancement (ENH) and vessel edge definition (VED)) and qualitatively. Results: First-pass MRA using the 3 doses of VSOP-C184 yielded the following ENH: aorta: 9.4 +/- 2.6; 12.31 +/- 1.2; 16.53 +/- 1.7; renal arteries: 7.6 +/- 2.2; 9.9 +/- 1.0; 13.2 +/- 0.5. The values for the 2 doses of Gd-DTPA were aorta: 12.9 +/- 1.0; 16.8 +/- 2.2; renal arteries: 11.2 +/- 1.23; 11.3 +/- 1.7. VED for the 3 doses of VSOP-C184 was aorta: 106.3 +/- 31.0; 135.3 +/- 58.8; 141.3 +/- 71.0; renal arteries: 102.2 +/- 24.3; 146.8 +/- 63.0; 126.9 +/- 37.6 and for the 2 doses of Gd-DTPA, aorta: 157.2 +/- 47.8; 164.2 +/- 36.8; renal arteries: 165.9 +/- 30.4; 170.3 +/- 38.2 respectively. The differences between VSOP-C184 and Gd-DTPA are clinically not relevant and statistically not significant (p greater than or equal to .05). Qualitative evaluation of image quality, contrast, and delineation of vessels showed the results obtained with VSOP-C184 at doses of 0.025 and 0.035 mmol Fe/kg to be similar to those of Gd-DTPA at 0.1 and 0.2 mmol Gd/kg. Conclusion: VSOP-C184 is suitable for first-pass MRA at doses of 0.025 and 0.035 mmol Fe/kg and thus, in addition to its blood pool characteristics, allows for selective visualization of the arteries without interfering venous signal.
引用
收藏
页码:546 / 553
页数:8
相关论文
共 42 条
[1]   Gadomer-17-enhanced 3D navigator-echo MR angiography of the pulmonary arteries in pigs [J].
Abolmaali, ND ;
Hietschold, V ;
Appold, S ;
Ebert, W ;
Vogl, TJ .
EUROPEAN RADIOLOGY, 2002, 12 (03) :692-697
[2]   Contrast-enhanced blood-pool MR angiography with optimized iron oxides: Effect of size and dose on vascular contrast enhancement in rabbits [J].
Allkemper, T ;
Bremer, C ;
Matuszewski, L ;
Ebert, W ;
Reimer, P .
RADIOLOGY, 2002, 223 (02) :432-438
[3]   Contrast-enhanced three-dimensional magnetic resonance angiography of atherosclerotic internal carotid stenosis as the noninvasive imaging modality in revascularization decision making [J].
Cosottini, M ;
Pingitore, A ;
Puglioli, M ;
Michelassi, MC ;
Lupi, G ;
Abbruzzese, A ;
Calabrese, R ;
Lombardi, M ;
Parenti, G ;
Bartolozzi, C .
STROKE, 2003, 34 (03) :660-664
[4]  
Cronberg CN, 2003, ACTA RADIOL, V44, P59
[5]   Toward comparability of coronary magnetic resonance angiography: proposal for a standardized quantitative assessment [J].
Dirksen, MS ;
Lamb, HJ ;
van der Geest, R ;
de Roos, A .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2353-2357
[6]   Preoperative evaluation of living renal donors:: value of contrast-enhanced 3D magnetic resonance angiography and comparison of three rendering algorithms [J].
Fink, C ;
Hallscheidt, PJ ;
Hosch, WP ;
Ott, RC ;
Wiesel, M ;
Kauffmann, GW ;
Düx, M .
EUROPEAN RADIOLOGY, 2003, 13 (04) :794-801
[7]  
Kellar KE, 1999, MAGN RESON MATER PHY, V8, P207
[8]   Gadobenate dimeglumine-enhanced MR angiography of the abdominal aorta and renal arteries [J].
Kroencke, TJ ;
Wasser, MN ;
Pattynama, PMT ;
Barentsz, JO ;
Grabbe, E ;
Marchal, G ;
Knopp, MV ;
Schneider, G ;
Bonomo, L ;
Pennell, DJ ;
Del Maschio, A ;
Hentrich, HR ;
Daprà, M ;
Kirchin, MA ;
Spinazzi, A ;
Taupitz, M ;
Hamm, B .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (06) :1573-1582
[9]  
La Noce A, 2002, ACAD RADIOL, V9, pS404
[10]   MS-325: Albumin-targeted contrast agent for MR angiography [J].
Lauffer, RB ;
Parmelee, DJ ;
Dunham, SU ;
Ouellet, HS ;
Dolan, RP ;
Witte, S ;
McMurry, TJ ;
Walovitch, RC .
RADIOLOGY, 1998, 207 (02) :529-538