Using antineutrophil cytoplasmic antibody testing to diagnose vasculitis -: Can test-ordering guidelines improve diagnostic accuracy?

被引:80
作者
Mandl, LA
Solomon, DH
Smith, EL
Lew, RA
Katz, JN
Shmerling, RH
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Rheumatol, Boston, MA 02115 USA
[2] Robert B Brigham Multipurpose Arthritis & Multipu, Boston, MA USA
[3] Brigham & Womens Hosp, Div Rheumatol Allergy & Immunol, Boston, MA 02115 USA
[4] Beth Israel Deaconess Med Ctr, Div Gen Med & Primary Care, Boston, MA 02215 USA
关键词
D O I
10.1001/archinte.162.13.1509
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Antineutrophil cytoplasmic antibodies (ANCAs) are strongly associated with Wegener granulomatosis, Churg-Strauss angiitis, microscopic polyangiitis, and pauci-immune glomerulonephritis, referred to collectively as ANCA-associated vasculitis (AAVs). It is unclear how accurate ANCA measurement is for diagnosing AAV in diverse populations or whether proposed ANCA test-ordering guidelines improve test performance. Methods: We assembled a retrospective case series of hospitalized and ambulatory patients from 2 academic medical centers to assess the diagnostic accuracy of ANCA measurement by enzyme-linked immunosorbent assay in identifying cases of AAV. In addition, we assessed the effect of applying proposed ANCA test-ordering guidelines on test performance. Results: For ANCA testing, sensitivity was 81% specificity, 98%; positive predictive value, 54%; and negative predictive value, 99%. There were no significant changes in operating characteristics after applying the guideline criteria. Using guidelines would have decreased ANCA test ordering by 23% and would have decreased the false-positive rate by 27%. No cases of AAV would have been missed if only patients fulfilling the guidelines were ANCA tested. Conclusion: A positive result on an enzyme-linked immunosorbent assay ANCA test, as it is currently ordered, is not a definitive diagnostic indicator of AAV. Compliance with guidelines for ANCA testing would decrease the number of false-positive results and has the potential to reduce total test expenditures.
引用
收藏
页码:1509 / 1514
页数:6
相关论文
共 30 条
[11]   Absence of cross-reactivity to myeloperoxidase of anti-thyroid microsomal antibodies in patients with autoimmune thyroid diseases [J].
Freire, BA ;
Paula, ID ;
Paula, F ;
Kallenberg, GGM ;
Limburg, PC ;
Queluz, TT .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2001, 321 (02) :109-112
[12]   LABORATORY CONSIDERATIONS IN THE DIAGNOSIS AND MANAGEMENT OF LYME BORRELIOSIS [J].
GOLIGHTLY, MG .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 99 (02) :168-174
[13]   Diagnostic value of standardized assays for anti-neutrophil cytoplasmic antibodies in idiopathic systemic vasculitis [J].
Hagen, EC ;
Daha, MR ;
Hermans, J ;
Andrassy, K ;
Csernok, E ;
Gaskin, G ;
Lesavre, P ;
Lüdemann, J ;
Rasmussen, N ;
Sinico, RA ;
Wiik, A ;
van der Woude, FJ .
KIDNEY INTERNATIONAL, 1998, 53 (03) :743-753
[14]  
Harris A, 2000, J CLIN PATHOL, V53, P644
[15]  
Hennekens C.H., 1987, EPIDEMIOLOGY MED
[16]  
Hoffman GS, 1998, ARTHRITIS RHEUM-US, V41, P1521, DOI 10.1002/1529-0131(199809)41:9<1521::AID-ART2>3.0.CO
[17]  
2-A
[18]   NOMENCLATURE OF SYSTEMIC VASCULITIDES - PROPOSAL OF AN INTERNATIONAL CONSENSUS CONFERENCE [J].
JENNETTE, JC ;
FALK, RJ ;
ANDRASSY, K ;
BACON, PA ;
CHURG, J ;
GROSS, WL ;
HAGEN, EC ;
HOFFMAN, GS ;
HUNDER, GG ;
KALLENBERG, CGM ;
MCCLUSKEY, RT ;
SINICO, RA ;
REES, AJ ;
VANES, LA ;
WALDHERR, R ;
WIIK, A .
ARTHRITIS AND RHEUMATISM, 1994, 37 (02) :187-192
[19]   FALSE-POSITIVE ANTINEUTROPHIL CYTOPLASMIC ANTIBODIES IN HIV-INFECTION [J].
KODERISCH, J ;
ANDRASSY, K ;
RASMUSSEN, N ;
HARTMANN, M ;
TILGEN, W .
LANCET, 1990, 335 (8699) :1227-1228
[20]   THE AMERICAN-COLLEGE-OF-RHEUMATOLOGY 1990 CRITERIA FOR THE CLASSIFICATION OF WEGENER GRANULOMATOSIS [J].
LEAVITT, RY ;
FAUCI, AS ;
BLOCH, DA ;
MICHEL, BA ;
HUNDER, GG ;
AREND, WP ;
CALABRESE, LH ;
FRIES, JF ;
LIE, JT ;
LIGHTFOOT, RW ;
MASI, AT ;
MCSHANE, DJ ;
MILLS, JA ;
STEVENS, MB ;
WALLACE, SL ;
ZVAIFLER, NJ .
ARTHRITIS AND RHEUMATISM, 1990, 33 (08) :1101-1107