Stability of high-performance liquid chromatography columns packed with poly(methyloctylsiloxane) sorbed and radiation-immobilized onto porous silica and zirconized silica

被引:36
作者
Melo, LFC [1 ]
Collins, CH [1 ]
Collins, KE [1 ]
Jardim, ICSF [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13083970 Campinas, SP, Brazil
关键词
gamma radiation; stationary phases; LC; column stability; poly(methyloctylsiloxane); zirconized silica;
D O I
10.1016/S0021-9673(99)00864-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reversed-phase packing materials were prepared from HPLC silica and from zirconized HPLC silica support particles having sorbed poly(methyloctylsiloxane) (PMOS) as the stationary phase. Portions of zirconized material were subjected to 80 kGy of ionizing radiation. Columns prepared from these packing materials were subjected to 5000 column volumes each of neutral and alkaline (pH 10) mobile phases, with periodic tests to evaluate chromatographic performance. It was shown that the PMOS stationary phase sorbed onto zirconized silica requires an immobilization treatment (such as gamma irradiation) for long term stability while prior surface zirconization of the silica support surface greatly improves the chromatographic stability of the stationary phase when using alkaline mobile phases. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 21 条
[1]   POLYMETHYLOCTILSILOXANE ADSORBED ON POROUS SILICA AS A PACKING MATERIAL FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ANAZAWA, TA ;
JARDIM, ICSF .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (06) :1265-1279
[2]   The chromatographic behavior of coated stationary phases with different silicas [J].
Anazawa, TA ;
Jardim, ICSF .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (05) :645-655
[3]   PREPARATION AND EVALUATION OF INORGANIC ANION-EXCHANGE SORBENTS NOT BASED ON SILICA [J].
CHICZ, RM ;
SHI, Z ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1986, 359 :121-130
[4]   Preparation of a C18 stationary phase immobilized by gamma radiation for use in high performance liquid chromatography [J].
da Silva, MCH ;
Jardim, ICSF .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (16) :2447-2458
[5]  
GUSHIKEM Y, 1991, NEW DEVELOPMENTS IN ION EXCHANGE, P607
[6]  
LI J, 1998, ANAL CHEM, V70, P1934
[7]   A study of the efficiency of polybutadiene-coated zirconia as a reversed-phase chromatographic support [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2193-2201
[8]   Effect of temperature on the thermodynamic properties, kinetic performance, and stability of polybutadiene-coated zirconia [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :837-843
[9]   Evaluation of temperature effects on selectivity in RPLC separations using polybutadiene-coated zirconia [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2202-2206
[10]   Retention characteristics of polybutadiene-coated zirconia and comparison to conventional bonded phases [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2857-2868