Stability of high-performance liquid chromatography columns packed with poly(methyloctylsiloxane) sorbed and radiation-immobilized onto porous silica and zirconized silica

被引:36
作者
Melo, LFC [1 ]
Collins, CH [1 ]
Collins, KE [1 ]
Jardim, ICSF [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13083970 Campinas, SP, Brazil
关键词
gamma radiation; stationary phases; LC; column stability; poly(methyloctylsiloxane); zirconized silica;
D O I
10.1016/S0021-9673(99)00864-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reversed-phase packing materials were prepared from HPLC silica and from zirconized HPLC silica support particles having sorbed poly(methyloctylsiloxane) (PMOS) as the stationary phase. Portions of zirconized material were subjected to 80 kGy of ionizing radiation. Columns prepared from these packing materials were subjected to 5000 column volumes each of neutral and alkaline (pH 10) mobile phases, with periodic tests to evaluate chromatographic performance. It was shown that the PMOS stationary phase sorbed onto zirconized silica requires an immobilization treatment (such as gamma irradiation) for long term stability while prior surface zirconization of the silica support surface greatly improves the chromatographic stability of the stationary phase when using alkaline mobile phases. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 21 条
[11]  
Melo LFC, 1999, J CHROMATOGR A, V845, P423
[12]   SELECTIVE SPECTROPHOTOMETRIC DETERMINATION OF TRACE AMOUNTS OF CHROMIUM(VI) USING A FLOW-INJECTION SYSTEM WITH A MICROCOLUMN OF ZIRCONIUM(IV) OXIDE MODIFIED SILICA-GEL [J].
PEIXOTO, CRM ;
GUSHIKEM, Y ;
BACCAN, N .
ANALYST, 1992, 117 (06) :1029-1032
[13]   Use of ruthenium-(ethylenedinitrito)-tetraacetic acid monohydrate ion immobilized on zirconium(IV) oxide coated silica gel surface as an amperometric sensor for oxygen in water [J].
Peixoto, CRM ;
Kubota, LT ;
Gushikem, Y .
ANALYTICAL PROCEEDINGS, 1995, 32 (12) :503-505
[14]  
Poole C.F., 1991, CHROMATOGRAPHY TODAY
[15]   Models for polybutadiene pore wall coatings in porous zirconia [J].
Reeder, DH ;
Li, JW ;
Carr, PW ;
Flickinger, MC ;
McCormick, AV .
JOURNAL OF CHROMATOGRAPHY A, 1997, 760 (01) :71-79
[16]   PREPARATION AND EVALUATION OF A POLYMER-COATED ZIRCONIA REVERSED-PHASE CHROMATOGRAPHIC SUPPORT [J].
RIGNEY, MP ;
WEBER, TP ;
CARR, PW .
JOURNAL OF CHROMATOGRAPHY, 1989, 484 :273-291
[17]   POROUS ZIRCONIA AND TITANIA AS PACKING MATERIALS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
TRUDINGER, U ;
MULLER, G ;
UNGER, KK .
JOURNAL OF CHROMATOGRAPHY, 1990, 535 (1-2) :111-125
[18]  
Unger KlausK., 1979, POROUS SILICA ITS PR
[19]   EVALUATION OF A ZIRCONIA-BASED CARBON POLYMER COMPOSITE REVERSED-PHASE CHROMATOGRAPHIC SUPPORT [J].
WEBER, TP ;
CARR, PW ;
FUNKENBUSCH, EF .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :31-52
[20]   REVERSED-PHASE LIQUID-CHROMATOGRAPHY OF DANSYL AMINO-ACIDS WITH MICROSPHERICAL OCTADECYL-SILICA AND OCTADECYL-ZIRCONIA BONDED STATIONARY PHASES [J].
YU, J ;
ELRASSI, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (14) :2931-2959