Gold screen-printed-based impedimetric immunobiosensors for direct and sensitive Escherichia coli quantisation

被引:75
作者
Escamilla-Gomez, Vanessa [1 ]
Campuzano, Susana [1 ]
Pedrero, Maria [1 ]
Pingarron, Jose M. [1 ]
机构
[1] Univ Complutense Madrid, Fac CC Quim, Dpto Quim Analit, E-28040 Madrid, Spain
关键词
E; coli; Immunosensors; Electrochemical impedance spectroscopy; Label-free detection; SURFACE-PLASMON RESONANCE; SELF-ASSEMBLED MONOLAYER; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ANTIBODY IMMOBILIZATION; FOOD SAMPLES; LABEL-FREE; IMMUNOSENSOR; O157-H7; SALMONELLA; BIOSENSOR;
D O I
10.1016/j.bios.2009.04.047
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Label-free electrochemical impedance immunosensors for the detection and quantification of Escherichia coli (E. coli) using self-assembled monolayers (SAMs)-modified gold screen-printed electrodes (AuSPEs) were developed. Two different immunosensor configurations were tested and compared. In the first one, the immunosensing design was based on the covalent immobilization of anti-E. coli at AuSPEs using the homobifunctional cross-linker 3,3'-dithiobis[sulfosuccinimidylpropionate] (DTSSP). The other one was based on the immobilization of the thiolated antibody onto the electrode surface. In both cases, the evaluation of the developed immunosensors performance was accomplished through the monitoring of the electron-transfer resistance detected by electrochemical impedance spectroscopy (EIS) in the presence of [Fe(CN)(6)(3-)]/[Fe(CN)(6)(4-)] as redox probe. The configuration using the thiolated antibodies gave rise to a better analytical performance, exhibiting a linear relationship between the increment in the electron-transfer resistance (Delta R-et) and the logarithmic value of the E. coli concentration in the 5-1.0 x 10(8) cfu mL(-1) range. The limit of detection achieved, with no need for preconcentration or pre-enrichment steps was 3.3 cfu mL(-1). The developed immunosensors showed a high selectivity against Staphylococcus aureus (S. aureus) and Salmonella choleraesuis (S. choleraesuis). The usefulness of the thiolated antibodies-based design for the rapid analysis (1 h) of 10 cfu mL(-1) E. coli inoculated river and tap water samples was demonstrated. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3365 / 3371
页数:7
相关论文
共 32 条
[1]   Sandwich electrochemical immunoassay for the detection of Staphylococcal enterotoxin B based on immobilized thiolated antibodies [J].
Chatrathi, Madhu Prakash ;
Wang, Joseph ;
Collins, Greg E. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) :2932-2938
[2]  
Dan D., 2007, TALANTA, V71, P1257
[3]   Heterogeneous immunosensing using antigen and antibody monolayers on gold surfaces with electrochemical and scanning probe detection [J].
Dong, YZ ;
Shannon, C .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2371-2376
[4]   Development of an immunosensor based on surface plasmon resonance for enumeration of Escherichia coli in water samples [J].
Dudak, Fahriye Ceyda ;
Boyaci, Ismail Hakki .
FOOD RESEARCH INTERNATIONAL, 2007, 40 (07) :803-807
[5]   Immunosensor for the determination of Staphylococcus aureus using a tyrosinase-mercaptopropionic acid modified electrode as an amperometric transducer [J].
Escamilla-Gomez, Vanessa ;
Campuzano, Susana ;
Pedrero, Maria ;
Pingarron, Jose M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (03) :837-845
[6]   Development of an amperometric immunosensor for the quantification of staphylococcus aureus using self-assembled monolayer-modiried electrodes as immobilization platforms [J].
Escamilla-Gomez, Vanessa ;
Campuzano, Susana ;
Pedrero, Maria ;
Pingarron, Jose M. .
ELECTROANALYSIS, 2007, 19 (14) :1476-1482
[7]   Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect salmonella in aqueous solution [J].
Fung, YS ;
Wong, YY .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5302-5309
[8]   Self-assembled monolayers-based immunosensor for detection of Escherichia coli using electrochemical impedance spectroscopy [J].
Geng, Ping ;
Zhang, Xinai ;
Meng, Weiwei ;
Wang, Qingjiang ;
Zhang, Wen ;
Jin, Litong ;
Feng, Zhen ;
Wu, Zirong .
ELECTROCHIMICA ACTA, 2008, 53 (14) :4663-4668
[9]   Entrapment of biomolecules in sol-gel matrix for applications in biosensors: Problems and future prospects [J].
Gupta, R. ;
Chaudhury, N. K. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2387-2399
[10]   Assembling of engineered IgG-binding protein on gold surface for highly oriented antibody immobilization [J].
Kanno, S ;
Yanagida, Y ;
Haruyama, T ;
Kobatake, E ;
Aizawa, M .
JOURNAL OF BIOTECHNOLOGY, 2000, 76 (2-3) :207-214