TLD extrapolation for skin dose determination in vivo

被引:45
作者
Kron, T [1 ]
Butson, M [1 ]
Hunt, F [1 ]
Denham, J [1 ]
机构
[1] ILLAWARRA CANC CARE CTR, WOLLONGONG, NSW 2500, AUSTRALIA
关键词
thermoluminescence dosimetry; skin dose determination;
D O I
10.1016/S0167-8140(96)01795-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Prediction of skin reactions requires knowledge of the dose at various depths in the human skin. Using thermoluminescence dosimeters of three different thicknesses, the dose can be extrapolated to the surface and interpolated between the different depths. A TLD holder was designed for these TLD extrapolation measurements on patients during treatment which allowed measurements of entrance and exit skin dose with a day to day variability of +/-7% (S.D. of mean reading). In a pilot study on 18 patients undergoing breast irradiation, it was found that the angle of incidence of the radiation beam is the most significant factor influencing skin entrance dose. In most of these measurements the beam exit dose contributed 50% more to the surface dose than the entrance dose.
引用
收藏
页码:119 / 123
页数:5
相关论文
共 18 条
[1]  
[Anonymous], ICRP PUBL
[2]   TANGENTIAL BREAST IRRADIATION - SIMPLE IMPROVEMENTS [J].
CROSS, P ;
JOSEPH, DJ ;
CANT, J ;
COOPER, SG ;
DENHAM, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (02) :433-442
[3]   SURFACE DOSE FROM MEGAVOLTAGE THERAPY MACHINES [J].
GAGNON, WF ;
GRANT, W .
RADIOLOGY, 1975, 117 (03) :705-708
[4]   ASSESSMENT OF SKIN DOSE AND ITS RELATION TO COSMESIS IN THE CONSERVATIVE TREATMENT OF EARLY BREAST-CANCER [J].
HABIBOLLAHI, F ;
MAYLES, HMO ;
MAYLES, WPM ;
WINTER, PJ ;
TONG, D ;
FENTIMAN, IS ;
CHAUDARY, MA ;
HAYWARD, JL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02) :291-296
[5]  
Hunt F., 1996, Radiographer, V43, P13
[6]  
International Commission on Radiation Units and Measurements, 1976, International Commission on Radiation Units and Measurements ICRU Report 24
[7]   ENTRANCE AND EXIT DOSE REGIONS FOR A CLINAC-2100C [J].
KLEIN, EE ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :429-435
[8]   X-RAY SURFACE DOSE MEASUREMENTS USING TLD EXTRAPOLATION [J].
KRON, T ;
ELLIOT, A ;
WONG, T ;
SHOWELL, G ;
CLUBB, B ;
METCALFE, P .
MEDICAL PHYSICS, 1993, 20 (03) :703-711
[9]   SKIN EXIT DOSE IN MEGAVOLTAGE X-RAY-BEAMS DETERMINED BY MEANS OF A PLANE-PARALLEL IONIZATION-CHAMBER (ATTIX CHAMBER) [J].
KRON, T ;
OSTWALD, P .
MEDICAL PHYSICS, 1995, 22 (05) :577-578
[10]  
KRON T, 1994, MED PHYS, V21, P968