Nonlinear phase interaction between nonstationary signals: A comparison study of methods based on Hilbert-Huang and Fourier transforms

被引:54
作者
Lo, Men-Tzung [1 ,2 ,3 ,4 ]
Novak, Vera [1 ]
Peng, C. -K. [2 ,3 ]
Liu, Yanhui [5 ]
Hu, Kun [1 ,6 ]
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Div Gerontol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Div Interdisciplinary Med & Biotechnol, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Margret & HA Rey Inst Nonlinear Dynam Med, Boston, MA 02215 USA
[4] Natl Cent Univ, Res Ctr Adapt Data Anal, Chungli 32054, Taiwan
[5] DynaDx Corp, Mountain View, CA 94041 USA
[6] Harvard Univ, Sch Med, Brigham & Womens Hosp, Div Sleep Med, Boston, MA 02215 USA
来源
PHYSICAL REVIEW E | 2009年 / 79卷 / 06期
关键词
EMPIRICAL MODE DECOMPOSITION; SPONTANEOUS BLOOD-PRESSURE; SPECTRAL-ANALYSIS; CEREBRAL AUTOREGULATION; SYSTEM-IDENTIFICATION; SYNCHRONIZATION; VARIABILITY;
D O I
10.1103/PhysRevE.79.061924
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Phase interactions among signals of physical and physiological systems can provide useful information about the underlying control mechanisms of the systems. Physical and biological recordings are often noisy and exhibit nonstationarities that can affect the estimation of phase interactions. We systematically studied effects of nonstationarities on two phase analyses including (i) the widely used transfer function analysis (TFA) that is based on Fourier decomposition and (ii) the recently proposed multimodal pressure flow (MMPF) analysis that is based on Hilbert-Huang transform (HHT)-an advanced nonlinear decomposition algorithm. We considered three types of nonstationarities that are often presented in physical and physiological signals: (i) missing segments of data, (ii) linear and step-function trends embedded in data, and (iii) multiple chaotic oscillatory components at different frequencies in data. By generating two coupled oscillatory signals with an assigned phase shift, we quantify the change in the estimated phase shift after imposing artificial nonstationarities into the oscillatory signals. We found that all three types of nonstationarities affect the performances of the Fourier-based and the HHT-based phase analyses, introducing bias and random errors in the estimation of the phase shift between two oscillatory signals. We also provided examples of nonstationarities in real physiological data (cerebral blood flow and blood pressure) and showed how nonstationarities can complicate result interpretation. Furthermore, we propose certain strategies that can be implemented in the TFA and the MMPF methods to reduce the effects of nonstationarities, thus improving the performances of the two methods.
引用
收藏
页数:11
相关论文
共 38 条
[1]   Deriving the respiratory sinus arrhythmia from the heartbeat time series using empirical mode decomposition [J].
Balocchi, R ;
Menicucci, D ;
Santarcangelo, E ;
Sebastiani, L ;
Gemignani, A ;
Ghelarducci, B ;
Varanini, M .
CHAOS SOLITONS & FRACTALS, 2004, 20 (01) :171-177
[2]   Scale invariance in the nonstationarity of human heart rate -: art. no. 168105 [J].
Bernaola-Galván, P ;
Ivanov, PC ;
Amaral, LAN ;
Stanley, HE .
PHYSICAL REVIEW LETTERS, 2001, 87 (16) :1-168105
[3]   Anisotropic seismic ground responses identified from the Hualien vertical array [J].
Chen, CH ;
Chiu, HC .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 1998, 17 (06) :371-395
[4]   Cross-correlation of instantaneous phase increments in pressure-flow fluctuations: Applications to cerebral autoregulation [J].
Chen, Z ;
Hu, K ;
Stanley, HE ;
Novak, V ;
Ivanov, PC .
PHYSICAL REVIEW E, 2006, 73 (03)
[5]   Eleven-year solar cycle signal throughout the lower atmosphere [J].
Coughlin, K ;
Tung, KK .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2004, 109 (D21) :D211051-7
[6]   11-year solar cycle in the stratosphere extracted by the empirical mode decomposition method [J].
Coughlin, KT ;
Tung, KK .
SOLAR VARIABILITY AND CLIMATE CHANGE, 2004, 34 (02) :323-329
[7]  
Duffy DG, 2004, J ATMOS OCEAN TECH, V21, P599, DOI 10.1175/1520-0426(2004)021<0599:TAOHTT>2.0.CO
[8]  
2
[9]  
FRIESEN WO, 1984, AM J PHYSIOL, V246, pR847, DOI 10.1152/ajpregu.1984.246.6.R847
[10]   Nonlinear assessment of cerebral autoregulation from spontaneous blood pressure and cerebral blood flow fluctuations [J].
Hu, Kun ;
Peng, C. K. ;
Czosnyka, Marek ;
Zhao, Peng ;
Novak, Vera .
CARDIOVASCULAR ENGINEERING, 2008, 8 (01) :60-71