Comparison of respiratory suppression methods and navigator locations for MR coronary angiography

被引:173
作者
McConnell, MV
Khasgiwala, VC
Savord, BJ
Chen, MH
Chuang, ML
Edelman, RR
Manning, WJ
机构
[1] CHARLES A DANA RES INST, DEPT MED, DIV CARDIOVASC, BOSTON, MA 02215 USA
[2] BETH ISRAEL DEACONESS MED CTR, HARVARD THORNDIKE LAB, BOSTON, MA 02215 USA
[3] BRIGHAM & WOMENS HOSP, DEPT MED, DIV CARDIOVASC, BOSTON, MA 02115 USA
[4] HARVARD UNIV, SCH MED, BOSTON, MA 02115 USA
[5] BETH ISRAEL DEACONESS MED CTR, DEPT RADIOL, BOSTON, MA 02215 USA
关键词
D O I
10.2214/ajr.168.5.9129447
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Currently, breath-holding during MR coronary angiography is used to minimize respiratory motion. This technique requires patient cooperation and is associated with slice registration errors, The goal of this study was to evaluate alternative non-breath-hold techniques for MR coronary angiography during free breathing. SUBJECTS AND METHODS. Subjects underwent MR coronary angiography using an EGG-gated, fat-suppressed, segmented K-space, gradient-echo sequence, Images were obtained during free breathing using both real-time navigator gating and respiratory bellows gating. These were compared with images obtained during conventional breath-holding. The optimal navigator location (diaphragmatic or cardiac) was also studied, Image quality, registration error, and scan time were measured for all scans. RESULTS. Navigator gating for MR coronary angiography during free breathing resulted in image quality equivalent to that obtained during breath-holding and was superior to that obtained with respiratory bellows gating (p <.04). Also, navigator gating reduced registration errors by 75% compared with breath-holding (p <.01) and did not increase scan time. No significant differences in the parameters measured were observed among the different navigator locations. CONCLUSION. Real-time navigator gating for MR coronary angiography during free breathing achieved image quality and scan time equivalent to breath-holding, Navigator gating also significantly reduced registration error. Compared with breath-holding and respiratory bellows gating, navigator gating during free breathing is a more optimal approach for suppression of respiratory motion during MR coronary angiography.
引用
收藏
页码:1369 / 1375
页数:7
相关论文
共 25 条
  • [1] CORONARY-ARTERY IMAGING IN MULTIPLE 1-SEC BREATH HOLDS
    DOYLE, M
    SCHEIDEGGER, MB
    DEGRAAF, RG
    VERMEULEN, J
    POHOST, GM
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (01) : 3 - 6
  • [2] 2-DIMENSIONAL CORONARY MR-ANGIOGRAPHY - ANALYSIS OF INITIAL CLINICAL-RESULTS
    DUERINCKX, AJ
    URMAN, MK
    [J]. RADIOLOGY, 1994, 193 (03) : 731 - 738
  • [3] FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    GERVINO, E
    LI, W
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 699 - 703
  • [4] MAGNETIC-RESONANCE IMAGING WITH RESPIRATORY GATING - TECHNIQUES AND ADVANTAGES
    EHMAN, RL
    MCNAMARA, MT
    PALLACK, M
    HRICAK, H
    HIGGINS, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1175 - 1182
  • [5] ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES
    EHMAN, RL
    FELMLEE, JP
    [J]. RADIOLOGY, 1989, 173 (01) : 255 - 263
  • [6] HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5
  • [7] HAACKE EM, 1995, TOP MAGN RESON IMAG, V7, P200
  • [8] HOFMAN MBM, 1995, J COMPUT ASSIST TOMO, V19, P56
  • [9] A MONITORING, FEEDBACK, AND TRIGGERING SYSTEM FOR REPRODUCIBLE BREATH-HOLD MR-IMAGING
    LIU, YL
    RIEDERER, SJ
    ROSSMAN, PJ
    GRIMM, RC
    DEBBINS, JP
    EHMAN, RL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) : 507 - 511
  • [10] A PRELIMINARY-REPORT COMPARING MAGNETIC-RESONANCE CORONARY ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY
    MANNING, WJ
    LI, W
    EDELMAN, RR
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (12) : 828 - 832