摘要
Membrane integrity fluorescent staining is used routinely to evaluate islet viability. Results are used as one of the determining factors in islet product release criteria, and are used to assess the efficacy of different culture conditions. Recently, it has been observed that there is variation in the viability staining of freshly isolated islets based on which viability assay is used. This investigation compares three membrane integrity stains for the viability assessment of isolated human islets. Fluorescein diacetate/propidium iodide (FDA/PI), the current standard method for assessing islet viability, demonstrates intense extracellular fluorescence, reducing the differential staining of intact islets. We further evaluated SYTO-13/ethidium bromide (SYTO/EB) and calcein AM/ethidium homodimer (C/EthD) as alternative viability assays, and found considerable variation between FDA/PI and either SYTO/EB or C/EthD staining. Preparations of human islets were obtained from cadaveric pancreata after collagenase digestion, mechanical separation, and purification by continuous Ficoll gradient centrifugation. For each preparation, two replicate samples of 50 islets were counted for each stain, and the percent viability calculated. The results for SYTO/EB and C/EthD were nearly identical [57.6 +/- 7.3% and 57.9 +/- 7.2%, respectively (mean +/- SEM), N = 11]. FDA/PI-stained islets, however, showed consistently elevated values when compared to SYTO/EB. Accurate assessment of islet viability remains a critical determinant of islet product release. The discrepancies found between FDA/PI scoring and visual quality, compared with alternative stains, suggests that the FDA/PI stain may not be the optimal approach to assess islet viability.
引用
收藏
页码:481 / 488
页数:8
相关论文
共 50 条
  • [1] BANK HL, 1987, DIABETOLOGIA, V30, P812
  • [2] BANK HL, 1988, IN VITRO CELL DEV B, V24, P266
  • [3] CHARACTERIZATION OF UPTAKE AND HYDROLYSIS OF FLUORESCEIN DIACETATE AND CARBOXYFLUORESCEIN DIACETATE BY INTRACELLULAR ESTERASES IN SACCHAROMYCES-CEREVISIAE, WHICH RESULT IN ACCUMULATION OF FLUORESCENT PRODUCT
    BREEUWER, P
    DROCOURT, JL
    BUNSCHOTEN, N
    ZWIETERING, MH
    ROMBOUTS, FM
    ABEE, T
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (04) : 1614 - 1619
  • [4] BRETZEL RG, 1994, TRANSPL P, V26, P388
  • [5] Potential problems with fluorescein diacetate assays of cell viability when testing natural products for antimicrobial activity
    Clarke, JM
    Gillings, MR
    Altavilla, N
    Beattie, AJ
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2001, 46 (03) : 261 - 267
  • [6] TEST OF GRANULOCYTE MEMBRANE INTEGRITY AND PHAGOCYTIC FUNCTION
    DANKBERG, F
    PERSIDSKY, MD
    [J]. CRYOBIOLOGY, 1976, 13 (04) : 430 - 432
  • [7] A comparison of media supplement methods for the extended culture of human islet tissue
    Fraga, DW
    Sabek, O
    Hathaway, DK
    Gaber, AO
    [J]. TRANSPLANTATION, 1998, 65 (08) : 1060 - 1066
  • [8] THE USE OF FLUORESCEIN DIACETATE AND ETHIDIUM-BROMIDE AS A VIABILITY STAIN FOR ISOLATED ISLETS OF LANGERHANS
    GRAY, DWR
    MORRIS, PJ
    [J]. STAIN TECHNOLOGY, 1987, 62 (06): : 379 - 381
  • [9] Use of nucleic acid dyes SYTO-13, TOTO-1, and YOYO-1 in the study of Escherichia coli and marine prokaryotic populations by flow cytometry
    Guindulain, T
    Comas, J
    VivesRego, J
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1997, 63 (11) : 4608 - 4611
  • [10] Haugland R.P., 2002, Handbook of Fluorescent Probes and Research Products, V9th