Model-based evaluation of the short-circuited tripolar cuff configuration

被引:4
作者
Andreasen, Lotte N. S. [1 ]
Struijk, Johannes J. [1 ]
机构
[1] Univ Aalborg, Ctr Sensory Motor Interact, DK-9220 Aalborg, Denmark
关键词
nerve cuff; cuff configuration; model; interfering signal modeling; single fiber action potentials;
D O I
10.1007/s11517-006-0057-x
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Recordings of neural information for use as feedback in functional electrical stimulation are often contaminated with interfering signals from muscles and from stimulus pulses. The cuff electrode used for the neural recording can be optimized to improve the S/I ratio. In this work, we evaluate a model of both the nerve signal and the interfering signals recorded by a cuff, and subsequently use this model to study the signal to interference ratio of different cuff designs and to evaluate a recently introduced short-circuited tripolar cuff configuration. The results of the model showed good agreement with results from measurements in rabbits and confirmed the superior performance of the short-circuited tripolar configuration as compared with the traditionally used tripolar configuration.
引用
收藏
页码:404 / 413
页数:10
相关论文
共 23 条
[1]   Artefact reduction with alternative cuff configurations [J].
Andreasen, LNS ;
Struijk, JJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (10) :1160-1166
[2]   Signal strength versus cuff length in nerve cuff electrode recordings [J].
Andreasen, LNS ;
Struijk, JJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (09) :1045-1050
[3]   Measurement of the performance of nerve cuff electrodes for recording [J].
Andreasen, LNS ;
Struijk, JJ ;
Lawrence, S .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (04) :447-453
[4]  
ANDREASEN LNS, 2000, P 5 ANN C IFESS SOC
[5]  
ANDREASEN LNS, 1999, P 1 JOINT BMES EMBS
[6]   SPECIFIC RESISTANCE OF BIOLOGICAL MATERIAL-A COMPENDUM OF DATA FOR BIOMEDICAL ENGINEER AND PHYSIOLOGIST [J].
GEDDES, LA ;
BAKER, LE .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03) :271-&
[7]   Modeling study of activation and propagation delays during stimulation of peripheral nerve fibers with a tripolar cuff electrode [J].
Goodall, Eleanor V. ;
Kosterman, L.Martin ;
Holsheimer, Jan ;
Struijk, Johannes J. .
IEEE Transactions on Rehabilitation Engineering, 1995, 3 (03) :272-282
[8]  
HAGULAND M, 1996, P 18 ANN INT C IEEE
[9]   Restoration of lateral hand grasp using natural sensors [J].
Haugland, M ;
Lickel, A ;
Riso, R ;
Adamczyk, MM ;
Keith, M ;
Jensen, IL ;
Haase, J ;
Sinkjaer, T .
ARTIFICIAL ORGANS, 1997, 21 (03) :250-253
[10]  
Haugland M. K., 1995, IEEE Transactions on Rehabilitation Engineering, V3, P307, DOI 10.1109/86.481970