The influence of contrast agents on hemorrhage produced by lithotripter fields

被引:71
作者
Dalecki, D
Raeman, CH
Child, SZ
Penney, DP
Mayer, R
Carstensen, EL
机构
[1] UNIV ROCHESTER,DEPT PATHOL,ROCHESTER,NY 14627
[2] UNIV ROCHESTER,DEPT UROL,ROCHESTER,NY 14627
关键词
contrast agent; Albunex(R); hemorrhage; lithotripter; mice; bioeffects;
D O I
10.1016/S0301-5629(97)00151-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasonic contrast agents greatly increase the side effects of low-amplitude lithotripter fields in mice. Using a piezoelectric lithotripter, adult mice were exposed to 200 Lithotripter pulses with a peak positive pressure amplitude of 2 MPa. During the exposure period, mice were injected with similar to 0.1 mt of the ultrasonic contrast agent Albunex(R). For comparison, another group of mice experienced the same lithotripter exposures, but were not injected with contrast agent. Following exposures, animals were sacrificed and observed for hemorrhage in various organs and tissues. Mice exposed to the lithotripter field alone had minimal hemorrhage only in the intestine and lung. In comparison, mice injected with Albunex(R) during exposure exhibited extensive hemorrhage in the intestine, kidney, muscle, mesentery, stomach, bladder, seminal vesicle and fat. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1435 / 1439
页数:5
相关论文
共 15 条
[1]   EFFECT OF A STABILIZED MICROBUBBLE ECHO CONTRAST AGENT ON HEMOLYSIS OF HUMAN ERYTHROCYTES EXPOSED TO HIGH-INTENSITY PULSED ULTRASOUND [J].
BRAYMAN, AA ;
AZADNIV, M ;
MAKIN, IRS ;
MILLER, MW ;
CARSTENSEN, EL ;
CHILD, SZ ;
RAEMAN, CH ;
MELTZER, RS ;
EVERBACH, EC .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1995, 12 (01) :13-21
[2]  
BRAYMAN AA, 1996, IN PRESS ULTRASOUND
[3]   THE CAVITATION THRESHOLD OF HUMAN TISSUE EXPOSED TO 0.2-MHZ PULSED ULTRASOUND - PRELIMINARY MEASUREMENTS BASED ON A STUDY OF CLINICAL LITHOTRIPSY [J].
COLEMAN, AJ ;
KODAMA, T ;
CHOI, MJ ;
ADAMS, T ;
SAUNDERS, JE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (03) :405-417
[4]   Hemolysis in vivo from exposure to pulsed ultrasound [J].
Dalecki, D ;
Raeman, CH ;
Child, SZ ;
Cox, C ;
Francis, CW ;
Meltzer, RS ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) :307-313
[5]   THRESHOLDS FOR INTESTINAL HEMORRHAGE IN MICE EXPOSED TO A PIEZOELECTRIC LITHOTRIPTER [J].
DALECKI, D ;
RAEMAN, CH ;
CHILD, SZ ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (09) :1239-1246
[6]   THRESHOLDS FOR PREMATURE VENTRICULAR CONTRACTIONS IN FROG HEARTS EXPOSED TO LITHOTRIPTER FIELDS [J].
DALECKI, D ;
KELLER, BB ;
CARSTENSEN, EL ;
NEEL, DS ;
PALLADINO, JL ;
NOORDERGRAAF, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (04) :341-346
[7]   A test for cavitation as a mechanism for intestinal hemorrhage in mice exposed to a piezoelectric lithotripter [J].
Dalecki, D ;
Raeman, CH ;
Child, SZ ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (04) :493-496
[8]   BIOLOGICAL EFFECTS OF SHOCK-WAVES - CAVITATION BY SHOCK-WAVES IN PIGLET LIVER [J].
DELIUS, M ;
DENK, R ;
BERDING, C ;
LIEBICH, HG ;
JORDAN, M ;
BRENDEL, W .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (05) :467-472
[9]  
DUNN F, 1977, ACUSTICA, V38, P58
[10]   LUNG DAMAGE FROM EXPOSURE TO THE FIELDS OF AN ELECTROHYDRAULIC LITHOTRIPTER [J].
HARTMAN, C ;
CHILD, SZ ;
MAYER, R ;
SCHENK, E ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (07) :675-679