Use of an intravascular T1 contrast agent to improve MR cine myocardial-blood pool definition in men

被引:38
作者
Stillman, AE
Wilke, N
JeroschHerold, M
机构
[1] Department of Radiology, University of Minnesota, Minneapolis, MN 55305
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 04期
关键词
MR imaging; cardiac MR; contrast agents; blood pool; cine;
D O I
10.1002/jmri.1880070425
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The feasibility of improving myocardial/blood pool contrast in NIR cine images through use of an intravascular contrast agent (Ferumoxtran, Advanced Magnetics, Inc., Cambridge, MA) was tested in four subjects, The contrast-to-noise ratio (CNR) demonstrated a trend toward improvement in the short axis and improved significantly in the long axis cine by an average of 128% (P < .05), Image intensity gradients at the myocardial/blood pool interface increased significantly in both the short and long axis (P < .01), It is expected that larger image intensity gradients at the endocardial border should improve the capabilities of automated segmentation algorithms, reducing the uncertainty and need for manual editing.
引用
收藏
页码:765 / 767
页数:3
相关论文
共 16 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]  
CHEN CW, 1994, IEEE T PATTERN ANAL, V16, P342, DOI 10.1109/34.277589
[3]   WHICH STANDARD HAS THE GOLD [J].
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1608-1609
[4]   PHYSICAL AND CHEMICAL-PROPERTIES OF SUPERPARAMAGNETIC IRON-OXIDE MR CONTRAST AGENTS - FERUMOXIDES, FERUMOXTRAN, FERUMOXSIL [J].
JUNG, CW ;
JACOBS, P .
MAGNETIC RESONANCE IMAGING, 1995, 13 (05) :661-674
[5]   REGIONAL DIFFERENCES IN RAT-BRAIN DISPLAYED BY FAST MRI WITH SUPERPARAMAGNETIC CONTRAST AGENTS [J].
MAJUMDAR, S ;
ZOGHBI, SS ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1988, 6 (06) :611-615
[6]   THE INFLUENCE OF PULSE SEQUENCE ON THE RELAXATION EFFECTS OF SUPERPARAMAGNETIC IRON-OXIDE CONTRAST AGENTS [J].
MAJUMDAR, S ;
ZOGHBI, SS ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (03) :289-301
[7]   PHASE-I CLINICAL-EVALUATION OF A NEW IRON-OXIDE MR CONTRAST AGENT [J].
MCLACHLAN, SJ ;
MORRIS, MR ;
LUCAS, MA ;
FISCO, RA ;
EAKINS, MN ;
FOWLER, DR ;
SCHEETZ, RB ;
OLUKOTUN, AY .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :301-307
[8]   IMPROVED CINE MR-IMAGING OF LEFT-VENTRICULAR WALL MOTION WITH GADOPENTETATE DIMEGLUMINE [J].
PENNELL, DJ ;
UNDERWOOD, SR ;
LONGMORE, DB .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :13-19
[9]   CARDIOVASCULAR MR IMAGING WITH IRON-OXIDE PARTICLES - UTILITY OF A SUPERPARAMAGNETIC CONTRAST AGENT AND THE ROLE OF DIFFUSION IN SIGNAL LOSS [J].
ROZENMAN, Y ;
ZOU, XM ;
KANTOR, HL .
RADIOLOGY, 1990, 175 (03) :655-659
[10]   NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING [J].
SEMELKA, RC ;
TOMEI, E ;
WAGNER, S ;
MAYO, J ;
KONDO, C ;
SUZUKI, J ;
CAPUTO, GR ;
HIGGINS, CB .
RADIOLOGY, 1990, 174 (03) :763-768