Liquid chromatographic determination using lanthanides as time-resolved luminescence probes for drugs and xenobiotics: Advantages and limitations

被引:48
作者
Rieutord, A
Prognon, P
Brion, F
Mahuzier, G
机构
[1] HOP ROBERT DEBRE,SERV PHARM,F-75019 PARIS,FRANCE
[2] HOP ROBERT DEBRE,LAB TOXICOPHARMACOL,F-75019 PARIS,FRANCE
关键词
lanthanides; energy transfer; time resolved luminescence; high-performance liquid chromatography; drugs; xenobiotics;
D O I
10.1039/a607616e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lanthanide sensitized luminescence is a very attractive alternative to UV detection and other luminescence techniques, i.e., fluorescence and phosphorescence, in separation science for the detection of drugs and xenobiotics because of the large Stokes shift, narrow emission bands and long lifetime, Some published applications of HPLC determination with lanthanide (Ln(3+)) sensitized luminescence detection are reviewed, Advantages and limitations of this technique are discussed, Normal-phase (NP) HPLC is not influenced by the quenching effect of water whereas reversed-phase (RP) HPLC is applicable to more compounds than NP-HPLC, However, pH adjustment and the quenching effect of water on Ln(3+) luminescence are the main drawbacks of RP-HPLC, Elution properties and the need for pH adjustment are two arguments for selecting the mode of addition of Ln(3+), i.e., pre- or post-column in the HPLC system, Sensitized Ln(3+) luminescence detection is a much more specific method of detection than UV or fluorescence detection after HPLC separation but nevertheless, in some cases, does not always exhibit a significant increase in analytical performance when the donor itself is a strong fluorophore. The development of more powerful excitation sources could improve the limit of detection of the Ln(3+) sensitized detection technique, This review suggests that it would be useful to obtain predicting factors about the drug to establish whether the latter is suitable to be measured using an HPLC-Ln(3+) approach.
引用
收藏
页码:R59 / R66
页数:8
相关论文
共 44 条
[1]   DETERMINATION OF STEROIDS IN URINE BY MICELLAR HPLC WITH DETECTION BY SENSITIZED TERBIUM FLUORESCENCE [J].
AMIN, M ;
HARRINGTON, K ;
VONWANDRUSZKA, R .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2346-2351
[2]  
BLANCHARD J, 1990, J CHROMATOGR SCI, V28, P203
[3]   LANTHANIDE COMPLEXATION - INNER VERSUS OUTER SPHERE [J].
CHOPPIN, GR ;
BERTHA, SL .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1973, 35 (04) :1309-1312
[4]  
DIAMANDIS EP, 1988, CLIN BIOCHEM, V21, P139, DOI 10.1016/0009-9120(88)90001-X
[5]   LANTHANIDE IONS AS LUMINESCENT CHROMOPHORES FOR LIQUID-CHROMATOGRAPHIC DETECTION [J].
DIBELLA, EE ;
WEISSMAN, JB ;
JOSEPH, MJ ;
SCHULTZ, JR ;
WENZEL, TJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 328 (JUN) :101-109
[6]   SENSITIZED ROOM-TEMPERATURE PHOSPHORESCENCE IN LIQUID SOLUTIONS WITH 1,4-DIBROMONAPHTHALENE AND BIACETYL AS ACCEPTORS [J].
DONKERBROEK, JJ ;
GOOIJER, C ;
VELTHORST, NH ;
FREI, RW .
ANALYTICAL CHEMISTRY, 1982, 54 (06) :891-895
[7]   PHOSPHORIMETRIC DETECTION IN HPLC VIA TRIVALENT LANTHANIDES - HIGH-SENSITIVITY TIME-RESOLVED LUMINESCENCE DETECTION OF TETRACYCLINES USING EU3+ IN A MICELLAR POST COLUMN REAGENT [J].
DUGGAN, JX .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (13) :2499-2525
[8]  
FARINOTTI R, 1983, THESIS U PARIS SUD
[9]   DETERMINATION OF URINARY OROTATE EXCRETION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FERRARI, V ;
GIORDANO, G ;
CRACCO, AT ;
DUSSINI, N ;
CHIANDETTI, L ;
ZACCHELLO, F .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 :101-107
[10]   LANTHANIDE-SENSITIZED LUMINESCENCE AND APPLICATIONS TO THE DETERMINATION OF ORGANIC ANALYTES - A REVIEW [J].
GEORGES, J .
ANALYST, 1993, 118 (12) :1481-1486