Apertureless near-field optical microscopy with differential and close-proximity detection

被引:14
作者
Fukuzawa, K
Tanaka, Y
机构
[1] NTT Integrated Information, Energy Systems Laboratories, Musashino-shi, Tokyo 180
关键词
D O I
10.1063/1.119492
中图分类号
O59 [应用物理学];
学科分类号
摘要
A new method of apertureless near-field optical microscopy that combines laterally differential detection with close-proximity detection has been developed. The laterally differential detection allows the light scattered from the probe apex to be distinguished from the background light. The close-proximity detection is done using a microfabricated photosensitive cantilever; it is thought to be a form of heterodyne detection, which provides a high signal level. This method makes it possible to detect the light scattered from the probe apex, which depends on the coupling between the probe apex dipole and the sample feature dipole. (C) 1997 American Institute of Physics.
引用
收藏
页码:169 / 171
页数:3
相关论文
共 17 条
[1]  
Akamine S, 1996, APPL PHYS LETT, V68, P579, DOI 10.1063/1.116504
[2]   SUPER-RESOLUTION APERTURE SCANNING MICROSCOPE [J].
ASH, EA ;
NICHOLLS, G .
NATURE, 1972, 237 (5357) :510-&
[3]   NEAR-FIELD OPTICS - MICROSCOPY, SPECTROSCOPY, AND SURFACE MODIFICATION BEYOND THE DIFFRACTION LIMIT [J].
BETZIG, E ;
TRAUTMAN, JK .
SCIENCE, 1992, 257 (5067) :189-195
[4]   COMBINED SHEAR FORCE AND NEAR-FIELD SCANNING OPTICAL MICROSCOPY [J].
BETZIG, E ;
FINN, PL ;
WEINER, JS .
APPLIED PHYSICS LETTERS, 1992, 60 (20) :2484-2486
[5]   Imaging of optical and topographical distributions by simultaneous near field scanning optical atomic force microscopy with a microfabricated photocantilever [J].
Fukuzawa, K ;
Tanaka, Y ;
Akamine, S ;
Kuwano, H ;
Yamada, H .
JOURNAL OF APPLIED PHYSICS, 1995, 78 (12) :7376-7381
[6]   NEAR-FIELD SCANNING OPTICAL MICROSCOPE WITH A METALLIC PROBE TIP [J].
INOUYE, Y ;
KAWATA, S .
OPTICS LETTERS, 1994, 19 (03) :159-161
[7]   NANOMETRIC SCALE BIOSAMPLE OBSERVATION USING A PHOTON SCANNING TUNNELING MICROSCOPE [J].
JIANG, S ;
OHSAWA, H ;
YAMADA, K ;
PANGARIBUAN, T ;
OHTSU, M ;
IMAI, K ;
IKAI, A .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1992, 31 (07) :2282-2287
[8]  
KELLER O, 1993, NEAR FIELD OPTICS, P229
[9]   DEVELOPMENT OF A 500-A SPATIAL-RESOLUTION LIGHT-MICROSCOPE .1. LIGHT IS EFFICIENTLY TRANSMITTED THROUGH GAMMA-16 DIAMETER APERTURES [J].
LEWIS, A ;
ISAACSON, M ;
HAROOTUNIAN, A ;
MURAY, A .
ULTRAMICROSCOPY, 1984, 13 (03) :227-231
[10]   NOVEL OPTICAL APPROACH TO ATOMIC FORCE MICROSCOPY [J].
MEYER, G ;
AMER, NM .
APPLIED PHYSICS LETTERS, 1988, 53 (12) :1045-1047