Miniaturized fluorescence detection chip for capillary electrophoresis immunoassay of agricultural herbicide atrazine

被引:19
作者
Shin, Kyeong-Sik
Kim, Young-Hwan
Min, Jung-Ah
Kwak, Seoung-Min
Kim, Sang Kyung
Yang, Eun Gyeong
Park, Jung-Ho
Ju, Byeong-Kwon
Kim, Tae-Song
Kang, Ji Yoon [1 ]
机构
[1] Korea Inst Sci & Technol, Microsyst Res Ctr, Seoul 136701, South Korea
[2] Korea Inst Sci & Technol, Biomed Res Ctr, Seoul 136701, South Korea
[3] Korea Univ, Dept Elect Engn, Seoul 136701, South Korea
关键词
capillary electrophoresis (CE); fluorescence detection chip; mircofluidic channel; polydimethylsiloxane (PDMS); photodiode; atrazine;
D O I
10.1016/j.aca.2006.05.099
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports a miniaturized fluorescence detection chip for capillary electrophoresis immumoassay of atrazine, which effectively reduces the size of fluorescence detection system. The photodiode with fluorescence filter was embedded in PDMS (polydimethylsiloxane) microfluidic chip and was placed just below the microfluidic channel. This detection chip is only few mm thick without loss of fluorescence due to the proximity of photodiode and channel. To investigate the feasibility of in situ detection of agricultural herbicide, atrazine was detected using capillary electrophoresis immunoassay in microfluidic chip. Mixture of 570 nM fluorescence-labeled atrazine (Ag*) and 700 nM anti-atrazine antibody (Ab) was injected and separated in 25 nun long microfluidic channel. The separated peaks of Ab-Ag* immunocomplex and Ag* were detected by the miniaturized detector and the change of peak magnitude was also observed with the variation of Ab concentration. The result was verified with those of external PMT (photomultiplier tube) and commercial capillary electrophoresis system. Hence, we have demonstrated the feasibility of portable CE immunoassay of atrazine with on-chip fluorescence detector. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 35 条
[1]   Microfluidic integration on detector arrays for absorption and fluorescence micro-spectrometers [J].
Adams, ML ;
Enzelberger, M ;
Quake, S ;
Scherer, A .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 104 (01) :25-31
[2]   PERFORMANCE OF CARBOHYDRATE-MODIFIED FUSED-SILICA CAPILLARIES FOR THE SEPARATION OF PROTEINS BY ZONE ELECTROPHORESIS [J].
BRUIN, GJM ;
HUISDEN, R ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :339-349
[3]   An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications [J].
Chabinyc, ML ;
Chiu, DT ;
McDonald, JC ;
Stroock, AD ;
Christian, JF ;
Karger, AM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4491-4498
[4]  
CHAMBERLAIN S, 1979, IEEE T ELECTRON DEV, V34, P7228
[5]   Variable-focusing microlens with microfluidic chip [J].
Chen, J ;
Wang, WS ;
Fang, J ;
Varahramyan, K .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (05) :675-680
[6]   Production and characterization of monoclonal antibodies specific to atrazine group compounds: Effects of coating ligand structure on the variation of sensitivity and specificity [J].
Choi, MJ ;
Jo, YA ;
Choi, JG ;
Kang, CY ;
Han, CT .
JOURNAL OF IMMUNOASSAY, 1999, 20 (1-2) :57-77
[7]   Development of single reagent for fluorescence polarization immunoassay of atrazine [J].
Choi, MJ ;
Lee, JR ;
Eremin, SA .
FOOD AND AGRICULTURAL IMMUNOLOGY, 2002, 14 (02) :107-120
[8]   Monitoring of herbicide pollution in water by capillary electrophoresis [J].
Dinelli, G ;
Vicari, A ;
Catizone, P .
JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) :337-347
[9]   Thin-film polymer light emitting diodes as integrated excitation sources for microscale capillary electrophoresis [J].
Edel, JB ;
Beard, NP ;
Hofmann, O ;
DeMello, JC ;
Bradley, DDC ;
deMello, AJ .
LAB ON A CHIP, 2004, 4 (02) :136-140
[10]   Capillary electrophoresis of pesticides [J].
El Rassi, Z .
ELECTROPHORESIS, 1997, 18 (12-13) :2465-2481