Hydrogen peroxide electrochemical detection for the development of protein film-modified sensor

被引:11
作者
Qiao, Yuanbiao [1 ]
Yang, Guang [1 ]
Jian, Fangfang [2 ]
Qin, Yongqi [2 ]
Yang, Lirong [1 ]
机构
[1] Zhejiang Univ, Coll Mat Sci & Chem Engn, Hangzhou 310027, Zhejiang, Peoples R China
[2] Qingdao Univ Sci & Technol, New Mat & Funct Coordinat Chem Lab, Qingdao 266042, Shandong, Peoples R China
关键词
Protein film voltammetry; Zr4+-nucleotide nanocomposite; Hydrogen peroxide sensor; GRAFTED-ZIRCONIA NANOPARTICLES; BY-LAYER FILMS; HORSERADISH-PEROXIDASE; AMPEROMETRIC BIOSENSOR; ELECTRON-TRANSFER; GOLD ELECTRODE; MYOGLOBIN; DNA; PHOSPHATE; IMMOBILIZATION;
D O I
10.1016/j.snb.2009.05.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A protein thin film-modified electrode sensor, that features both generalizability and simplicity in design toward reagentless detection of hydrogen peroxide with high sensitivity and reliability, is reported here. Within this electrode device, the film active material of the nanocomposite of myoglobin and zirconium (iv) ion-adenosine monophosphate dianion particles forming via monolayer adsorption of protein, is fabricated on a glassy carbon surface using self-assembly technique. The electrode modification helps in facilitating the direct electron transfer kinetics of protein at the formal potential (E degrees') of 12.3 mV versus SHE (pH 7.0). As a result, the potential applied in H2O2 determination through reduction can be shifted to -3.7 mV, a useful characteristic for further applications. Furthermore, the electrode configuration provides Sufficient operational stability for sensing. Detection limit of 0.06 mu M and the linear calibration range up to 148.47 mu M H2O2 are obtained for this sensor. The sensor assay can retain a value of 91.7% initial activity within 1 month. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 25 条
[1]   HETEROGENEOUS AND HOMOGENEOUS ELECTRON TRANSFERS TO AROMATIC HALIDES - ELECTROCHEMICAL REDOX CATALYSIS STUDY IN THE HALOBENZENE AND HALOPYRIDINE SERIES [J].
ANDRIEUX, CP ;
BLOCMAN, C ;
DUMASBOUCHIAT, JM ;
SAVEANT, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1979, 101 (13) :3431-3441
[2]  
Antonini E., 1971, Hemoglobin and Myoglobin in. Their Reactions with Ligands
[3]  
Bard A.J., 2001, ELECTROCHEMICAL METH
[4]   Immobilization of myoglobin on phosphate and phosphonate grafted-zirconia nanoparticles [J].
Bellezza, F ;
Cipiciani, A ;
Quotadamo, MA .
LANGMUIR, 2005, 21 (24) :11099-11104
[5]   Structure, stability, and activity of myoglobin adsorbed onto phosphate-grafted zirconia nanoparticles [J].
Bellezza, Francesca ;
Cipiciani, Antonio ;
Quotadarno, Maria Anna ;
Cinelli, Stefania ;
Onori, Giuseppe ;
Tacchi, Silvia .
LANGMUIR, 2007, 23 (26) :13007-13012
[6]   Fracture toughness, strength and slow crack growth in a ceria stabilized zirconia-alumina nanocomposite for medical applications [J].
Benzaid, Rajaa ;
Chevalier, Jerome ;
Saddaoui, Malika ;
Fantozzi, Gilbert ;
Nawa, Masahiro ;
Diaz, Luis Antonio ;
Torrecillas, Ramon .
BIOMATERIALS, 2008, 29 (27) :3636-3641
[7]   Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane [J].
Chen, XH ;
Hu, YB ;
Wilson, GS .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1005-1013
[8]   Hydrogen peroxide biosensor based on DNA-Hb modified gold electrode [J].
Kafi, AKM ;
Yin, F ;
Shin, HK ;
Kwon, YS .
THIN SOLID FILMS, 2006, 499 (1-2) :420-424
[9]   Prussian Blue-based 'artificial peroxidase' as a transducer for hydrogen peroxide detection. Application to biosensors [J].
Karyakin, AA ;
Karyakina, EE .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 57 (1-3) :268-273
[10]   Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: Routes to impedimetric immunosensors, DNA-Sensors, and enzyme biosensors [J].
Katz, E ;
Willner, I .
ELECTROANALYSIS, 2003, 15 (11) :913-947