Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy

被引:57
作者
Schaumann, A
vonzurMuhlen, F
Gonska, BD
Kreuzer, H
机构
[1] University of Göttingen, Department of Cardiology
关键词
D O I
10.1016/S0002-9149(96)00501-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this prospective study was to evaluate the efficacy and safety of enhanced detection criteria, stability and sudden onset, for ventricular tachycardia (VT) in the therapy of implantable cardioverter-defibrillators (ICDs). These detection enhancements ensure a high specificity in detecting VT, thereby avoiding inappropriate therapy delivery due to supraventricular tachycardia. However, delayed sensing or even undersensing of VT may lead to a problematic, even fatal, outcome. In our study, the stability detection enhancement was programmed to discriminate atrial fibrillation (AF) in 84 of 124 patients with implanted ICDs and the sudden-onset detection enhancement in 47 of the 124 patients to discriminate sinus tachycardia. Using these enhancements in 124 patients with third-generation ICDs, 13 patients (11%) had inappropriate therapy during 20 months of follow-up. AF caused shock delivery in 6 patients (5%) and antitachycardia pacing in 4 patients, atrial flutter triggered shock therapy in 1 patient, and sinus tachycardia caused shock delivery in 2 patients. In 3 of the 13 patients inappropriate therapy recurred despite reprogramming the detection enhancements. The stability parameter of 241 spontaneous VT episodes as measured by the devices was 8 +/- 7 msec. Only 10 (4%) VTs had a stability parameter >25 msec. In 46 patients a combination of both detection enhancements, stability and/or sudden onset, were programmed. The use of detection enhancements proved safe and no patient had suffered negative side effects due to prolonged detection time or therapy delay. Inappropriate shock delivery due to AF, ct major complication in ICD therapy, was reduced to 5% of patients. The use of the stability enhancement is recommended for patients with intermittent or chronic AF. Selected patients profit from programming both the stability and sudden onset criteria.
引用
收藏
页码:42 / 50
页数:9
相关论文
共 22 条
[1]   HOLTER DOCUMENTED SUDDEN-DEATH IN A PATIENT WITH AN IMPLANTED DEFIBRILLATOR [J].
BIRGERSDOTTERGREEN, U ;
ROSENQVIST, M ;
LINDEMANS, FW ;
RYDEN, L ;
RADEGRAN, K .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (07) :1008-1014
[2]  
BOCKER D, 1993, J AM COLL CARDIOL, V21, P1638
[3]   IMPLANTABLE CARDIOVERTER DEFIBRILLATOR PROARRHYTHMIA - CASE-REPORT AND REVIEW OF THE LITERATURE [J].
COHEN, TJ ;
CHIEN, WW ;
LURIE, KG ;
LEE, MA ;
LESH, MD ;
SCHEINMAN, MM ;
GRIFFIN, JC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (09) :1326-1329
[4]   ACTUARIAL INCIDENCE AND PATTERN OF OCCURRENCE OF SHOCKS FOLLOWING IMPLANTATION OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
FOGOROS, RN ;
ELSON, JJ ;
BONNET, CA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (09) :1465-1473
[5]   AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - PATIENT SURVIVAL, BATTERY LONGEVITY AND SHOCK DELIVERY ANALYSIS [J].
GABRY, MD ;
BRODMAN, R ;
JOHNSTON, D ;
FRAME, R ;
KIM, SG ;
WASPE, LE ;
FISHER, JD ;
FURMAN, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (06) :1349-1356
[6]   ELECTROCARDIOGRAPHICALLY DOCUMENTED UNNECESSARY, SPONTANEOUS SHOCKS IN 241 PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS [J].
GRIMM, W ;
FLORES, BF ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1667-1673
[7]   NONTHORACOTOMY DEFIBRILLATOR IMPLANTATION - A SINGLE-CENTER EXPERIENCE WITH 200 PATIENTS [J].
HAMMEL, D ;
SCHELD, HH ;
BLOCK, M ;
BREITHARDT, G .
ANNALS OF THORACIC SURGERY, 1994, 58 (02) :321-327
[8]  
HERSE B, 1994, Z HERZ THORAX GEFASS, V8, P7
[9]   IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY IN THE ABSENCE OF SIGNIFICANT SYMPTOMS - RHYTHM DIAGNOSIS AND MANAGEMENT AIDED BY STORED ELECTROGRAM ANALYSIS [J].
HOOK, BG ;
CALLANS, DJ ;
KLEIMAN, RB ;
FLORES, BT ;
MARCHLINSKI, FE .
CIRCULATION, 1993, 87 (06) :1897-1906
[10]   ARRHYTHMIAS INDUCED BY DEVICE ANTITACHYCARDIA THERAPY DUE TO DIAGNOSTIC NONSPECIFICITY [J].
JOHNSON, NJ ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (05) :1418-1425