A new approach to the determination of column overload characteristics in reversed-phase liquid chromatography

被引:29
作者
Dai, Jun [2 ]
Carr, Peter W. [1 ]
McCalley, David V. [3 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
[2] Bristol Myers Squibb, Princeton, NJ 08540 USA
[3] Univ W England, Biomed Res Ctr, Bristol BS16 1QY, Avon, England
关键词
Overload; Langmuirian non-linear chromatography; Limiting plate count; Column sample loading capacity; CRAIG DISTRIBUTION MODEL; POLYBUTADIENE-COATED ZIRCONIA; STRONGLY BASIC COMPOUNDS; SILANE BONDED SILICA; COMPUTER-SIMULATIONS; NONLINEAR CHROMATOGRAPHY; LINEAR CHROMATOGRAPHY; ISOCRATIC CONDITIONS; IONIZABLE COMPOUNDS; LANGMUIR ISOTHERM;
D O I
10.1016/j.chroma.2009.01.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Column overloading is very common during the separations of basic analytes in analytical scale reversed-phase liquid chromatography (RPLC). Due to the complex interactions of ionic analytes with stationary and mobile phases, only a very small amount of ionized sample compared to the amount of nonpolar solute can be injected before the peak shape is distorted by non-linear chromatographic processes. Often the amount that can be injected before overload is observed is so small that the signal is quite noisy, thereby making the measured plate count imprecise and possibly inaccurate. The Purpose of the present study was to develop a practical method for the precise measurement of the plate count and a column overload parameter using a simple but mathematically rigorous model of Langmuirian non-linear chromatography. An "overload profile", i.e. a plot of apparent plate count versus amount injected, is characterized by two parameters: the limiting plate count(N-0)and the column sample loading capacity (omega(0.5)). The limiting plate count is the plate count that should be observed when the amount of sample injected is so small that a linear isotherm pertains. The column sample loading capacity, which is taken as the sample load that leads to a plate count equal to half of the limiting plate count, is a measure of the maximum amount of sample that can be injected into that column. The approach was tested by applying it to the study of cationic analytes in RPLC. We show that No under constant conditions (column length, flow rate, mobile phase composition, etc.) is almost independent of column type (manufacturer); however, different column types (at the same length, diameter and flow rate) exhibit clear differences in their sample loading capacity (omega(0.5)). We believe that for most well packed type B columns, the column sample loading capacity and not the limiting plate count is the more important property that accounts for most of the apparent differences in peak width when different types of columns are examined. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2474 / 2482
页数:9
相关论文
共 41 条
[1]   LIQUID-CHROMATOGRAPHY PLATE HEIGHT EQUATIONS [J].
ARNOLD, FH ;
BLANCH, HW ;
WILKE, CR .
JOURNAL OF CHROMATOGRAPHY, 1985, 330 (01) :159-166
[2]  
Bidlingmeyer B.A., 1987, PREPARATIVE LIQUID C
[3]   ESTIMATING ERROR LIMITS IN PARAMETRIC CURVE FITTING [J].
CACECI, MS .
ANALYTICAL CHEMISTRY, 1989, 61 (20) :2324-2327
[4]   PREPARATIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY UNDER ISOCRATIC CONDITIONS .3. THE CONSEQUENCES OF 2 ADJACENT BANDS HAVING UNEQUAL COLUMN CAPACITIES [J].
COX, GB ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1989, 483 :95-110
[5]   Role of ion pairing in anionic additive effects on the separation of cationic drugs in reversed-phase liquid chromatography [J].
Dai, J ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (02) :169-184
[6]   Comparison of the chromatography of octadecyl silane bonded silica and polybutadiene-coated zirconia phases based on a diverse set of cationic drugs [J].
Dai, J ;
Yang, XQ ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1005 (1-2) :63-82
[7]  
DAI J, IN PRESS
[8]   ISOTHERM LINEARITY AND SAMPLE CAPACITY IN LIQUID-CHROMATOGRAPHY [J].
DEJONG, AWJ ;
KRAAK, JC ;
POPPE, H ;
NOOITGEDACHT, F .
JOURNAL OF CHROMATOGRAPHY, 1980, 193 (02) :181-195
[9]   SIMPLIFIED DESCRIPTION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION UNDER OVERLOAD CONDITIONS, BASED ON THE CRAIG DISTRIBUTION MODEL .1. COMPUTER-SIMULATIONS FOR A SINGLE ELUTION BAND ASSUMING A LANGMUIR ISOTHERM [J].
EBLE, JE ;
GROB, RL ;
ANTLE, PE ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :25-44
[10]   SIMPLIFIED DESCRIPTION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION UNDER OVERLOAD CONDITIONS, BASED ON THE CRAIG DISTRIBUTION MODEL .2. EFFECT OF ISOTHERM TYPE, AND EXPERIMENTAL-VERIFICATION OF COMPUTER-SIMULATIONS FOR A SINGLE BAND [J].
EBLE, JE ;
GROB, RL ;
ANTLE, PE ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :45-79