Usefulness of concurrent reading using thin-section and thick-section CT images in subcentimetre solitary pulmonary nodules

被引:28
作者
Lee, H. Y.
Goo, J. M. [1 ]
Lee, H. J.
Lee, C. H.
Park, C. M.
Park, E. -A.
Im, J. -G.
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
关键词
GROUND-GLASS OPACITY; EARLY LUNG-CANCER; VOLUMETRIC MEASUREMENT; STATEMENT;
D O I
10.1016/j.crad.2008.09.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the differences in the characterization and recommendation for follow-up of subcentimetre solitary pulmonary nodules (SSPNs) between 5 and 1 mm section CT, and to compare the assessments generated by four radiologists MATERIALS AND METHODS: Five hundred and twenty-nine patients who had SSPNs on chest CT reconstructed using both 5 and 1 mm sections were enrolled. Two image subsets of 5 and 1 mm CT images of each nodule were interpreted independently by four radiologists. Nodule size, consistency (solid, partly solid, non-solid), the presence of calcification, and recommendations for follow-up were evaluated. If a non-calcified solid nodule was confirmed using CT, recommendation for follow-up was based on Fleischner Society guidelines. Data assessed by each radiologist were compared, and interobserver agreements were determined using the intraclass correlation coefficients and kappa value. RESULTS: Using 1 mm CT images, the nodule sizes were significantly larger than on 5 mm CT images (paired t-test, p < 0.01). The presence of calcification and nodule consistency were significantly different between 5 and 1 mm CT images (McNemar test for the presence of calcification, p < 0.01; Wilcoxon signed test for nodule consistency, p < 0.01). On 1 mm CT images there was significantly higher agreement regarding nodule consistency than on 5 mm CT (kappa - 0.78 and 0.67, respectively). CONCLUSIONS: Concurrent use of thin-section and thick-section CT can provide more accurate nodule assessment and higher interobserver agreement in SSPN. (c) 2008 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 20 条
[1]   A consensus statement of the society of thoracic radiology - Screening for lung cancer with helical computed tomography [J].
Aberle, DR ;
Gamsu, G ;
Henschke, CI ;
Naidich, DP ;
Swensen, SJ .
JOURNAL OF THORACIC IMAGING, 2001, 16 (01) :65-68
[2]   Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer [J].
Brenner, DJ .
RADIOLOGY, 2004, 231 (02) :440-445
[3]   Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers [J].
Diederich, S ;
Wormanns, D ;
Semik, M ;
Thomas, M ;
Lenzen, H ;
Roos, N ;
Heindel, W .
RADIOLOGY, 2002, 222 (03) :773-781
[4]   Lung cancer: Interobserver agreement on interpretation of pulmonary findings at low-dose CT screening [J].
Gierada, David S. ;
Pilgram, Thomas K. ;
Ford, Melissa ;
Fagerstrom, Richard M. ;
Church, Timothy R. ;
Nath, Hrudaya ;
Garg, Kavita ;
Strollo, Diane C. .
RADIOLOGY, 2008, 246 (01) :265-272
[5]   Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy [J].
Goo, JM ;
Tongdee, T ;
Tongdee, R ;
Yeo, K ;
Hildebolt, CF ;
Bae, KT .
RADIOLOGY, 2005, 235 (03) :850-856
[6]   Growth rate of small lung cancers detected on mass CT screening [J].
Hasegawa, M ;
Sone, S ;
Takashima, S ;
Li, F ;
Yang, ZG ;
Maruyama, Y ;
Watanabe, T .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876) :1252-1259
[7]   CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules [J].
Henschke, CI ;
Yankelevitz, DF ;
Mirtcheva, R ;
McGuinness, G ;
McCauley, D ;
Miettinen, OS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) :1053-1057
[8]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105
[9]   Automated detection of pulmonary nodules on CT images: Effect of section thickness and reconstruction interval - Initial results [J].
Kim, JS ;
Kim, JH ;
Cho, GS ;
Bae, KT .
RADIOLOGY, 2005, 236 (01) :295-299
[10]   Malignant versus benign nodules at CT screening for lung cancer: Comparison of thin-section CT findings [J].
Li, F ;
Sone, S ;
Abe, H ;
MacMhon, H ;
Doi, K .
RADIOLOGY, 2004, 233 (03) :793-798