New method for the determination of benzoic and sorbic acids in commercial orange juices based on second-order spectrophotometric data generated by a pH gradient flow injection technique

被引:46
作者
Marsili, NR
Lista, A
Band, BSF
Goicoechea, HC
Olivieri, AC
机构
[1] Univ Nacl Litoral, Fac Bioquim & Ciencias Biol, Catedra Quim Anal, RA-3000 Santa Fe, Argentina
[2] Univ Nacl Sur, Dept Quim, Lab FIA Quim Analit, Bahia Blanca, Buenos Aires, Argentina
[3] N Dakota State Univ, Dept Chem & Mol Biol, Fargo, ND 58105 USA
[4] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, Dept Quim Anal, RA-2000 Rosario, Argentina
关键词
flow injection analysis; pH gradient; parallel factor analysis; multivariate curve resolution; benzoic acid; sorbic acid; food analysis;
D O I
10.1021/jf035362f
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Two widely employed antimicrobials, benzoic and sorbic acids, were simultaneously determined in commercial orange juices employing a combination of a flow injection system with pH gradient generation, diode array spectro photometric detection, and chemometric processing of the recorded second-order data. Parallel factor analysis and multivariate curve resolution-alternating least-squares were used for obtaining the spectral profiles of sample components and concentration profiles as a function of pH, including provisions for managing rank-deficient data sets. An appropriately designed calibration with a nine-sample set of binary mixtures of standards, coupled to the use of the second-order advantage offered by the applied chemometric techniques, allowed quantitation of the analytes in synthetic test samples and also in commercial orange juices, even in the presence of unmodeled interferents (with relative prediction errors of 8.7% for benzoic acid and 2.5% for sorbic acid). No prior separation or sample pretreatment steps were required. The comparison of results concerning commercial samples with a laborious reference technique yielded satisfactory statistical indicators (recoveries were 99.0% for benzoic acid and 101.4% for sorbic acid).
引用
收藏
页码:2479 / 2484
页数:6
相关论文
共 31 条
[1]  
[Anonymous], 1987, BINDING CONSTANTS ME
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]   Multivariate calibration of polycyclic aromatic hydrocarbon mixtures from excitation-emission fluorescence spectra [J].
Beltrán, JL ;
Ferrer, R ;
Guiteras, J .
ANALYTICA CHIMICA ACTA, 1998, 373 (2-3) :311-319
[4]   Simultaneous determination of antioxidants, preservatives and sweeteners permitted as additives in food by mixed micellar electrokinetic chromatography [J].
Boyce, MC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 847 (1-2) :369-375
[5]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[6]  
CAPUTI A, 1974, J ASSOC OFF ANA CHEM, V57, P951
[7]  
CAPUTI A, 1975, J ASSOC OFF ANA CHEM, V58, P133
[8]   SIMULTANEOUS 2ND-ORDER DERIVATIVE SPECTROPHOTOMETRIC DETERMINATION OF SORBIC AND BENZOIC-ACIDS IN SOFT DRINKS [J].
CASTRO, JCG ;
DELGADO, MAR ;
SANCHEZ, MJ ;
MONTELONGO, FG .
ANALYTICAL LETTERS, 1992, 25 (12) :2367-2376
[9]   Purity assessment and resolution of tetracycline hydrochloride samples analysed using high-performance liquid chromatography with diode array detection [J].
De Braekeleer, K ;
de Juan, A ;
Massart, DL .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :67-86
[10]   Quantitation of mixtures of diprotic organic acids by FT-IR flow titrations and multivariate curve resolution [J].
Diewok, J ;
De Juan, A ;
Tauler, R ;
Lendl, B .
APPLIED SPECTROSCOPY, 2002, 56 (01) :40-50