Development of a high-performance capillary isoelectric focusing technique with application to studies of microheterogeneity in chicken conalbumin

被引:27
作者
Huang, TL [1 ]
Richards, M [1 ]
机构
[1] USDA ARS,BELTSVILLE,MD 20705
关键词
conalbumin; metalloproteins;
D O I
10.1016/S0021-9673(96)00684-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A robust, simple, reproducible isoelectric focusing method using capillary electrophoresis that exhibits high stability, migration time reproducibility and pH linearity over a wide pH gradient was developed. Consecutive runs (over 113 runs) of several proteins and one peptide with isoelectric points (pIs) ranging from 9.45 to 2.75 yielded excellent migration time reproducibility (<2% R.S.D.). Experimental parameters including buffer aging and capillary-to-capillary variation were thoroughly examined and optimized to improve the migration time reproducibility. The capillary isoelectric focusing (CIEF) method was applied to the analysis of chicken conalbumin (ovotransferrin), an iron-binding protein in egg white. Conalbumin (low iron content) separated into three major components with pls of 7.2, 6.6 and 6.2. When the protein was saturated with iron (2 Fe/mol), a shift to lower pls was detected. Chicken serum transferrin subjected to CIEF gave a pattern similar to conalbumin with three pls of 7.1, 6.6 and 6.1, indicating that it was not fully saturated with iron. Thus, CIEF can be used as a potential analytical method to provide information about the metal-binding properties of specific metalloproteins.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 25 条
[1]   ISOELECTRIC-FOCUSING OF HISTONES IN EXTREMELY ALKALINE IMMOBILIZED PH GRADIENTS - COMPARISON WITH CAPILLARY ELECTROPHORESIS [J].
BOSSI, A ;
GELFI, C ;
ORSI, A ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY A, 1994, 686 (01) :121-128
[2]   ISOELECTRIC-FOCUSING BY FREE SOLUTION CAPILLARY ELECTROPHORESIS [J].
CHEN, SM ;
WIKTOROWICZ, JE .
ANALYTICAL BIOCHEMISTRY, 1992, 206 (01) :84-90
[3]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[4]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61
[5]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[6]   THEORETICAL AND EXPERIMENTAL-STUDY OF HIGH-PERFORMANCE ELECTROPHORETIC MOBILIZATION OF ISOELECTRICALLY FOCUSED PROTEIN ZONES [J].
HJERTEN, S ;
LIAO, JL ;
YAO, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :127-138
[7]  
HUANG TH, 1995, 7 INT S HIGH PERF CA
[8]   ISOELECTRIC-FOCUSING OF PROTEINS IN CAPILLARY ELECTROPHORESIS WITH PRESSURE-DRIVEN MOBILIZATION [J].
HUANG, TL ;
SHIEH, PCH ;
COOKE, N .
CHROMATOGRAPHIA, 1994, 39 (9-10) :543-548
[9]   EVALUATION OF A NEUTRAL HYDROPHILIC COATED CAPILLARY FOR CAPILLARY ZONE ELECTROPHORETIC SEPARATION OF PROTEINS [J].
HUANG, TL ;
SHIEH, PCH ;
KOH, EV ;
COOKE, N .
JOURNAL OF CHROMATOGRAPHY A, 1994, 685 (02) :313-320
[10]   Non-bonded poly(ethylene oxide) polymer-coated column for protein separation by capillary electrophoresis [J].
Iki, N ;
Yeung, ES .
JOURNAL OF CHROMATOGRAPHY A, 1996, 731 (1-2) :273-282