Multivariate optimization and validation studies in on-line pre-concentration system for lead determination in drinking water and saline waste from oil refinery

被引:90
作者
dos Santos, WL [1 ]
dos Santos, CMM [1 ]
Costa, JLO [1 ]
Andrade, HMC [1 ]
Ferreira, SLC [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
关键词
on-line pre-concentration system; lead determination; oil refinery;
D O I
10.1016/j.microc.2004.02.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper proposes an on-line pre-concentration procedure for lead determination in drinking water and saline waste from oil refinery by flame atomic absorption spectrometry (FAAS). It is based on the sorption of lead (II) ions in a minicolumn of polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol (PAR) reagent. The optimization step was performed using Doehlert matrix involving the variables: sampling flow rate (SR), buffer concentration (BC), pH and eluent concentration (EC). The validation process was performed considering the parameters: linearity and other characteristics of the calibration curve, analytical features of on-line system, precision, robustness, effect of other ions in the pre-concentration system and accuracy. Using the established experimental conditions, the procedure allows lead determination with detection limit (3delta/S) of 0.4 mug l(-1), quantification limit (10delta/S) of 1.4 mug l(-1), and a precision, calculated as relative standard deviation (RSD) of 5.7 (n=8) and 2.1% (n=8) for lead concentration of 5 and 50 mug l(-1), respectively. The pre-concentration factor (PF) considering the ratio among the slopes of the analytical curves with and without pre-concentration is 51. The achieved recovery for lead determination in presence of several cations demonstrated that this procedure could be applied for analysis of water samples. The accuracy was confirmed by analysis of the standard reference material NIST 1640 Trace elements in natural water. The sorption process was characterized by the Langmuir isotherm. The method was applied for lead determination in drinking water collected in Salvador City, Brazil and in saline effluent samples from oil refinery. The lead content for 16 samples of drinking water analyzed varied from 0.77 to 6.98 mug l(-1). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 36 条
[21]   Optimisation and validation of a capillary electrophoresis method for the simultaneous determination of diazepam and otilonium bromide [J].
Furlanetto, S ;
Orlandini, S ;
Massolini, G ;
Faucci, MT ;
La Porta, E ;
Pinzauti, S .
ANALYST, 2001, 126 (10) :1700-1706
[22]   On-line preconcentration system for lead determination in seafood samples by flame atomic absorption spectrometry using polyurethane foam loaded with 2-(2-benzothiazolylazo)-2-p-cresol [J].
Lemos, VA ;
Ferreira, SLC .
ANALYTICA CHIMICA ACTA, 2001, 441 (02) :281-289
[23]   Simultaneous determination of trace level bromate and chlorinated haloacetic acids in bottled drinking water by ion chromatography [J].
Liu, YJ ;
Mou, SF .
MICROCHEMICAL JOURNAL, 2003, 75 (02) :79-86
[24]   The application of cloud point preconcentration for the determination of Cu in real samples by flame atomic absorption spectrometry [J].
Manzoori, JL ;
Bavili-Tabrizi, A .
MICROCHEMICAL JOURNAL, 2002, 72 (01) :1-7
[25]   Speciation of Cr(VI)/Cr(III) in environmental waters by fluorimetric method using central composite, full and fractional factorial design [J].
Massumi, A ;
Najafi, NM ;
Barzegari, H .
MICROCHEMICAL JOURNAL, 2002, 72 (01) :93-101
[26]  
*MIN SAUD, 2000, PORT 1469
[27]   Determination of zinc in environmental samples by solid phase spectrophotometry: Optimization and validation study [J].
Molina, MF ;
Nechar, M ;
Bosque-Sendra, M .
ANALYTICAL SCIENCES, 1998, 14 (04) :791-797
[28]   Trends in preconcentration procedures for metal determination using atomic spectrometry techniques [J].
Pereira, MD ;
Arruda, MAZ .
MICROCHIMICA ACTA, 2003, 141 (3-4) :115-131
[29]   Arsenic determination in naphtha by electrothermal atomic absorption spectrometry after preconcentration using multiple injections [J].
Reboucas, MV ;
Ferreira, SLC ;
Neto, BDB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (10) :1267-1273
[30]   A new approach to a complete robustness test of experimental nominal conditions of chemical testing procedures for internal analytical quality assessment [J].
Rodriguez, LC ;
Garcia, RB ;
Campana, AMG ;
Sendra, JMB .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 41 (01) :57-68