Complex dielectric measurements and analysis of brain tissues in the radio and microwave frequencies

被引:61
作者
Bao, JZ
Lu, ST
Hurt, WD
机构
[1] USA, MED RES DETACHMENT, BROOKS AFB, TX 78235 USA
[2] ARMSTRONG LAB, BROOKS AFB, TX 78235 USA
关键词
brain tissues; complex dielectric constant; complex nonlinear modeling; open-ended coaxial probe technique; radio and microwave frequencies;
D O I
10.1109/22.641720
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present in-vitro complex dielectric measurements of gray and white matter of rat brains in the frequency range between 45 MHz and 26.5 GHz at body and room temperatures using the open-ended coaxial probe technique with an HP8510B network analyzer. The measurement data exhibited two separated dispersions, and were analyzed by means of a complex nonlinear least-squares technique. We suggest two empirical models to describe the experimental data: one containing two Cole-Cole functions was applied to the data from this paper, and another including one Havriliak-Negami and one Cole-Cole function was utilized to a combination of past and present literature data in a wider frequency range from 100 kHz to 26.5 GHz. The adoption of previously published data at the frequencies below 45 MHz increases the valid frequency range of the model.
引用
收藏
页码:1730 / 1741
页数:12
相关论文
共 25 条
[1]   MEASUREMENT OF RADIO-FREQUENCY PERMITTIVITY OF BIOLOGICAL TISSUES WITH AN OPEN-ENDED COAXIAL LINE .1. [J].
ATHEY, TW ;
STUCHLY, MA ;
STUCHLY, SS .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1982, 30 (01) :82-86
[2]  
B??ttcher C. J. F., 1980, THEORY ELECT POLARIZ
[3]   ANALYSIS OF AN OPEN-ENDED COAXIAL PROBE WITH LIFT-OFF FOR NONDESTRUCTIVE TESTING [J].
BAKERJARVIS, J ;
JANEZIC, MD ;
DOMICH, PD ;
GEYER, RG .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1994, 43 (05) :711-718
[4]   IMPEDANCE SPECTROSCOPY OF HUMAN ERYTHROCYTES - SYSTEM CALIBRATION AND NONLINEAR MODELING [J].
BAO, JZ ;
DAVIS, CC ;
SCHMUKLER, RE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (04) :364-378
[5]   MICROWAVE DIELECTRIC MEASUREMENTS OF ERYTHROCYTE SUSPENSIONS [J].
BAO, JZ ;
DAVIS, CC ;
SWICORD, ML .
BIOPHYSICAL JOURNAL, 1994, 66 (06) :2173-2180
[6]   Microwave dielectric characterization of binary mixtures of water, methanol, and ethanol [J].
Bao, JZ ;
Swicord, ML ;
Davis, CC .
JOURNAL OF CHEMICAL PHYSICS, 1996, 104 (12) :4441-4450
[7]   Open-ended metallized ceramic coaxial probe for high-temperature dielectric properties measurements [J].
Bringhurst, S ;
Iskander, MF .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (06) :926-935
[8]   INVIVO PROBE MEASUREMENT TECHNIQUE FOR DETERMINING DIELECTRIC-PROPERTIES AT VHF THROUGH MICROWAVE-FREQUENCIES [J].
BURDETTE, EC ;
CAIN, FL ;
SEALS, J .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1980, 28 (04) :414-427
[9]  
Chou CK, 1996, BIOELECTROMAGNETICS, V17, P195, DOI 10.1002/(SICI)1521-186X(1996)17:3<195::AID-BEM5>3.0.CO
[10]  
2-Z