摘要
This study compares the main commercial detectors that can detect amino acids in their underivatized form. The detectors tested are: the chemiluminescent nitrogen detector (CLND), the evaporative light scattering detector (ELSD), the nuclear magnetic resonance spectrometer, conductivity detector, refractive index, UV, and electrospray quadrupole mass spectrometry (in simple and tandem MS mode). As ELSD, CLND and MS require a volatile mobile phase, an ion-pair reversed-phase liquid chromatographic system was selected, consisting of an octadecyl column and an aqueous mobile phase containing pentadecafluorooctanoic acid as volatile ion-pairing reagent. Underivatized taurine, hypotaurine, aspartic acid, hydroxyproline, asparagine, serine, glycine, glutamine, cysteine, glutamic acid, threonine and alanine were simultaneously analysed with each detector. In order to test the applicability of these detectors to "real world" samples, the amino acid stoichiometry of the tetrapeptide Gly-Gly-Asp-Ala was determined with each detector after acid hydrolysis. The detectors were compared in terms of linearity, limit of detection, advantages and disadvantages as well as special features (capacity to provide structural information, specificity, quantification with single calibration curve, etc.). (C) 2002 Elsevier Science BV All rights reserved.
引用
收藏
页码:9 / 21
页数:13
相关论文
共 124 条
[1]   Detection of amino acids at conducting electroactive polymer modified electrodes using flow injection analysis .2. Use of microelectrodes [J].
Akhtar, P ;
Too, CO ;
Wallace, GG .
ANALYTICA CHIMICA ACTA, 1997, 339 (03) :211-223
[2]  
Akhtar P, 1997, ANAL CHIM ACTA, V339, P201, DOI 10.1016/S0003-2670(96)00477-1
[3]   APPLICATION OF A COPPER TUBULAR ELECTRODE AS A POTENTIOMETRIC DETECTOR IN THE DETERMINATION OF AMINO-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ALEXANDER, PW ;
HADDAD, PR ;
LOW, GKC ;
MAITRA, C .
JOURNAL OF CHROMATOGRAPHY, 1981, 209 (01) :29-39
[4]   INDIRECT DETECTION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY - RESPONSE DEVIATIONS IN ION-PAIRING SYSTEMS [J].
ARVIDSSON, E ;
CROMMEN, J ;
SCHILL, G ;
WESTERLUND, D .
JOURNAL OF CHROMATOGRAPHY, 1989, 461 :429-441
[5]   DIRECT ANALYSIS OF PEPTIDES AND AMINO-ACIDS FROM CAPILLARY ELECTROPHORESIS [J].
BERGMAN, T ;
AGERBERTH, B ;
JORNVALL, H .
FEBS LETTERS, 1991, 283 (01) :100-103
[6]   Applications of packed-column SFC using light-scattering detection [J].
Berry, AJ ;
Ramsey, ED ;
Newby, M ;
Games, DE .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1996, 34 (05) :245-253
[7]  
Bhushan R, 1996, BIOMED CHROMATOGR, V10, P37, DOI 10.1002/(SICI)1099-0801(199601)10:1<37::AID-BMC547>3.0.CO
[8]  
2-P
[9]   Chemiluminescent detection of amines and amino acids using in situ generated Ru(bpy)33+ following separation by capillary electrophoresis [J].
Bobbitt, DR ;
Jackson, WA ;
Hendrickson, HP .
TALANTA, 1998, 46 (04) :565-572
[10]   Detection of native amino acids and peptides utilizing sinusoidal voltammetry [J].
Brazill, SA ;
Singhal, P ;
Kuhr, WG .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5542-5548