A comparative study of commercial liquid chromatographic detectors for the analysis of underivatized amino acids

被引:135
作者
Petritis, K [1 ]
Elfakir, C [1 ]
Dreux, M [1 ]
机构
[1] Univ Orleans, CNRS, UMR 6005, ICOA, F-45067 Orleans 2, France
关键词
detection; LC; evaporative light scattering detection; nuclear magnetic resonance; mass spectrometry; chemiluminescent nitrogen detection; refractive index detection; UV detection; conductivity detection; ion-pairing reagents; amino acids;
D O I
10.1016/S0021-9673(02)00377-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study compares the main commercial detectors that can detect amino acids in their underivatized form. The detectors tested are: the chemiluminescent nitrogen detector (CLND), the evaporative light scattering detector (ELSD), the nuclear magnetic resonance spectrometer, conductivity detector, refractive index, UV, and electrospray quadrupole mass spectrometry (in simple and tandem MS mode). As ELSD, CLND and MS require a volatile mobile phase, an ion-pair reversed-phase liquid chromatographic system was selected, consisting of an octadecyl column and an aqueous mobile phase containing pentadecafluorooctanoic acid as volatile ion-pairing reagent. Underivatized taurine, hypotaurine, aspartic acid, hydroxyproline, asparagine, serine, glycine, glutamine, cysteine, glutamic acid, threonine and alanine were simultaneously analysed with each detector. In order to test the applicability of these detectors to "real world" samples, the amino acid stoichiometry of the tetrapeptide Gly-Gly-Asp-Ala was determined with each detector after acid hydrolysis. The detectors were compared in terms of linearity, limit of detection, advantages and disadvantages as well as special features (capacity to provide structural information, specificity, quantification with single calibration curve, etc.). (C) 2002 Elsevier Science BV All rights reserved.
引用
收藏
页码:9 / 21
页数:13
相关论文
共 124 条
[31]  
DOU L, 1990, Biochromatography, V5, P74
[32]  
Dreux M., 1996, LC GC INTERNATIONAL, V9, P148
[33]  
Edman P., 1975, Protein Sequence Determination: A Sourcebook of Methods and Techniques, Molecular Biology Biochemistry and Biophysics, P232, DOI [10.1007/978-3-642-80945-3_8, DOI 10.1007/978-3-642-80945-3_8]
[34]   COPPER WIRE AMPEROMETRIC DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
ENGSTROMSILVERMAN, CE ;
EWING, AG .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (02) :141-145
[35]   SEPARATION AND INDIRECT DETECTION OF AMINO-ACIDS BY REVERSED-PHASE ION-PAIR CHROMATOGRAPHY [J].
ESLAMI, M ;
HASHEMI, P ;
SARBOLOUKI, MN .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1993, 31 (11) :480-485
[36]   State-of-the-art of high-performance liquid chromatographic analysis of amino acids in physiological samples [J].
Fekkes, D .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 682 (01) :3-22
[37]   BIOAVAILABILITY PREDICTION OF AMINO-ACIDS AND PEPTIDES IN NUTRITIVE MIXTURES BY SEPARATION ON NONPOLAR STATIONARY PHASES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND DIRECT UV DETECTION AT 210 NM [J].
FIALAIRE, A ;
POSTAIRE, E ;
PROGNON, R ;
PRADEAU, D .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (14) :3003-3015
[38]   SIMULTANEOUS ANALYSIS OF METHIONINE-ENKEPHALIN AND LEUCINE-ENKEPHALIN FROM RAT-BRAIN - QUANTIFICATION BY LIQUID-CHROMATOGRAPHY - ELECTROCHEMISTRY [J].
FLEMING, LH ;
REYNOLDS, NC .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 431 (01) :65-76
[39]   SEPARATION AND DETECTION OF CLOSELY RELATED ENDORPHINS BY LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY [J].
FLEMING, LH ;
REYNOLDS, NC .
JOURNAL OF CHROMATOGRAPHY, 1986, 375 (01) :65-73
[40]   THEORETICAL-STUDY OF SYSTEM PEAKS IN LINEAR CHROMATOGRAPHY [J].
GOLSHANSHIRAZI, S ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1990, 62 (09) :923-932