A novel multithreshold method for nodule detection in lung CT

被引:66
作者
Golosio, Bruno [1 ,2 ]
Masala, Giovanni Luca [1 ,2 ]
Piccioli, Alessio [1 ,2 ]
Oliva, Piernicola [1 ,2 ]
Carpinelli, Massimo [1 ,2 ]
Cataldo, Rosella [3 ,4 ]
Cerello, Piergiorgio [5 ]
De Carlo, Francesco [6 ,7 ]
Falaschi, Fabio [8 ]
Fantacci, Maria Evelina [9 ,10 ]
Gargano, Gianfranco [6 ,7 ]
Kasae, Parnian [10 ,11 ]
Torsello, Massimo [12 ]
机构
[1] Univ Sassari, Struttura Dipartimentale Matemat & Fis, I-07100 Sassari, Italy
[2] Ist Nazl Fis Nucl, Sez Cagliari, I-09042 Monserrato, CA, Italy
[3] Univ Salento, Dipartimento Sci Mat, I-73100 Lecce, Italy
[4] Ist Nazl Fis Nucl, Sez Lecce, I-73100 Lecce, Italy
[5] Ist Nazl Fis Nucl, Sez Torino, I-10125 Turin, Italy
[6] Univ Bari, Dipartimento Fis, I-70126 Bari, Italy
[7] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
[8] Univ Pisa, Osped Cisanello, UO Radiodiagnost 2, I-56124 Pisa, Italy
[9] Univ Pisa, Dipartimento Fis, I-56127 Pisa, Italy
[10] Ist Nazl Fis Nucl, Sez Pisa, I-56127 Pisa, Italy
[11] Univ Siena, Dipartimento Fis, I-53100 Siena, Italy
[12] Osped Vito Fazzi, Unita Operat Radiol, I-73100 Lecce, Italy
关键词
cancer; computerised tomography; feature extraction; lung; medical image processing; DOSE SPIRAL CT; COMPUTED-TOMOGRAPHY IMAGES; AUTOMATED DETECTION; PULMONARY NODULES; DATABASE CONSORTIUM; AIDED DIAGNOSIS; CANCER; SCANS; POPULATION; PREVALENCE;
D O I
10.1118/1.3160107
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Multislice computed tomography (MSCT) is a valuable tool for lung cancer detection, thanks to its ability to identify noncalcified nodules of small size (from about 3 mm). Due to the large number of images generated by MSCT, there is much interest in developing computer-aided detection (CAD) systems that could assist radiologists in the lung nodule detection task. A complete multistage CAD system, including lung boundary segmentation, regions of interest (ROIs) selection, feature extraction, and false positive reduction is presented. The selection of ROIs is based on a multithreshold surface-triangulation approach. Surface triangulation is performed at different threshold values, varying from a minimum to a maximum value in a wide range. At a given threshold value, a ROI is defined as the volume inside a connected component of the triangulated isosurface. The evolution of a ROI as a function of the threshold can be represented by a treelike structure. A multithreshold ROI is defined as a path on this tree, which starts from a terminal ROI and ends on the root ROI. For each ROI, the volume, surface area, roundness, density, and moments of inertia are computed as functions of the threshold and used as input to a classification system based on artificial neural networks. The method is suitable to detect different types of nodules, including juxta-pleural nodules and nodules connected to blood vessels. A training set of 109 low-dose MSCT scans made available by the Pisa center of the Italung-CT trial and annotated by expert radiologists was used for the algorithm design and optimization. The system performance was tested on an independent set of 23 low-dose MSCT scans coming from the Pisa Italung-CT center and on 83 scans made available by the Lung Image Database Consortium (LIDC) annotated by four expert radiologists. On the Italung-CT test set, for nodules having a diameter greater than or equal to 3 mm, the system achieved 84% and 71% sensitivity at false positive/scan rates of 10 and 4, respectively. For nodules having a diameter greater than or equal to 4 mm, the sensitivities were 97% and 80% at false positive/scan rates of 10 and 4, respectively. On the LIDC data set, the system achieved a 79% sensitivity at a false positive/scan rate of 4 in the detection of nodules with a diameter greater than or equal to 3 mm that have been annotated by all four radiologists.
引用
收藏
页码:3607 / 3618
页数:12
相关论文
共 43 条
[1]
A real-time classification system of thalassemic pathologies based on artificial neural networks [J].
Amendolia, SR ;
Brunetti, A ;
Carta, P ;
Cossu, G ;
Ganadu, ML ;
Golosio, B ;
Mura, GM ;
Pirastru, MG .
MEDICAL DECISION MAKING, 2002, 22 (01) :18-26
[2]
[Anonymous], 1988, Morphological methods in image and signal processing
[3]
Computerized scheme for automated detection of lung nodules in low-dose computed tomography images for lung cancer screening [J].
Arimura, H ;
Katsuragawa, S ;
Suzuki, K ;
Li, F ;
Shiraishi, J ;
Sone, S ;
Doi, K .
ACADEMIC RADIOLOGY, 2004, 11 (06) :617-629
[4]
Evaluation of automated lung nodule detection on low-dose computed tomography scans from a lung cancer screening program [J].
Armato, SG ;
Roy, AS ;
MacMahon, H ;
Li, F ;
Doi, K ;
Sone, S ;
Altman, MB .
ACADEMIC RADIOLOGY, 2005, 12 (03) :337-346
[5]
Lung image database consortium: Developing a resource for the medical imaging research community [J].
Armato, SG ;
McLennan, G ;
McNitt-Gray, MF ;
Meyer, CR ;
Yankelevitz, D ;
Aberle, DR ;
Henschke, CI ;
Hoffman, EA ;
Kazerooni, EA ;
MacMahon, H ;
Reeves, AP ;
Croft, BY ;
Clarke, LP .
RADIOLOGY, 2004, 232 (03) :739-748
[6]
Automated lung nodule classification following automated nodule detection on CT: A serial approach [J].
Armato, SG ;
Altman, MB ;
Wilkie, J ;
Sone, S ;
Li, F ;
Doi, K ;
Roy, AS .
MEDICAL PHYSICS, 2003, 30 (06) :1188-1197
[7]
Automated detection of lung nodules in CT scans:: Effect of image reconstruction algorithm [J].
Armato, SG ;
Altman, MB ;
La Rivière, PJ .
MEDICAL PHYSICS, 2003, 30 (03) :461-472
[8]
Automated detection of lung nodules in CT scans: Preliminary results [J].
Armato, SG ;
Giger, ML ;
MacMahon, H .
MEDICAL PHYSICS, 2001, 28 (08) :1552-1561
[9]
Pulmonary nodules: Automated detection on CT images with morphologic matching algorithm preliminary results [J].
Bae, KT ;
Kim, JS ;
Na, YH ;
Kim, KG ;
Kim, JH .
RADIOLOGY, 2005, 236 (01) :286-294
[10]
A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model [J].
Bellotti, R. ;
De Carlo, F. ;
Gargano, G. ;
Tangaro, S. ;
Cascio, D. ;
Catanzariti, E. ;
Cerello, P. ;
Cheran, S. C. ;
Delogu, P. ;
De Mitri, I. ;
Fulcheri, C. ;
Grosso, D. ;
Retico, A. ;
Squarcia, S. ;
Tommasi, E. ;
Golosio, Bruno .
MEDICAL PHYSICS, 2007, 34 (12) :4901-4910