On-line monitoring of formaldehyde in air by cataluminescence-based gas sensor

被引:115
作者
Zhou, Kaowen [1 ]
Ji, Xiaolin
Zhang, Nan
Zhang, Xinrong
机构
[1] Beijing Union Univ, Biochem Engn Coll, Beijing 100023, Peoples R China
[2] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2006年 / 119卷 / 02期
关键词
formaldehyde; cataluminescence; gas sensor; nanosized material;
D O I
10.1016/j.snb.2005.12.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive cataluminescence (CTL)-based gas sensor using nanosized V2Ti4O13 as a probe was proposed for the determination of formaldehyde in air. The gas sensor showed high selectivity for formaldehyde at 490nm and satisfying activity at 370 degrees C. The linear range of the CTL intensity versus concentration of formaldehyde was 0.1-40 mg/m(3) (gamma=0.9995), and the detection limit (3 sigma) was 0.06 mg/m(3). No interference was observed while the foreign substances, such as ammonia, ethanol, benzene, carbon monoxide and sulfur dioxide, were passing through the sensor. The gas sensor displayed good stability for continuously introducing formaldehyde over 80 h, and allowed on-line monitoring of formaldehyde in air. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:392 / 397
页数:6
相关论文
共 38 条
[1]   CHEMILUMINESCENCE DURING CATALYSIS OF CARBON-MONOXIDE OXIDATION ON A THORIA SURFACE [J].
BREYSSE, M ;
CLAUDEL, B ;
FAURE, L ;
GUENIN, M ;
WILLIAMS, RJJ ;
WOLKENSTEIN, T .
JOURNAL OF CATALYSIS, 1976, 45 (02) :137-144
[2]   Atmospheric formaldehyde monitoring in the greater Houston area in 2002 [J].
Chen, JH ;
So, S ;
Lee, HS ;
Fraser, MP ;
Curl, RF ;
Harman, T ;
Tittel, FK .
APPLIED SPECTROSCOPY, 2004, 58 (02) :243-247
[3]   Conductometric formaldehyde sensitive biosensor with specifically adapted analytical characteristics [J].
Dzyadevych, SV ;
Arkhypova, VN ;
Korpan, YI ;
El'skaya, AV ;
Soldatkin, AP ;
Jaffrezic-Renault, N ;
Martelet, C .
ANALYTICA CHIMICA ACTA, 2001, 445 (01) :47-55
[4]  
FAN J, 2003, INT J ENVIRON AN CH, V82, P361
[5]   Kinetic spectrophotometric determination of formaldehyde in fabric and air by sequential injection analysis [J].
Feng, SL ;
Fan, J ;
Wang, AJ ;
Chen, XG ;
Hui, ZD .
ANALYTICAL LETTERS, 2004, 37 (12) :2545-2555
[6]   Spectrophotometric determination of formaldehyde with chromotropic acid in phosphoric acid medium assisted by microwave oven [J].
Gigante, AC ;
Gotardo, MA ;
Tognolli, JO ;
Pezza, L ;
Pezza, HR .
MICROCHEMICAL JOURNAL, 2004, 77 (01) :47-51
[7]  
Giovanni B., 2004, ANAL CHIM ACTA, V511, P155
[8]  
HELOISA LC, 2004, MICROCHEM J, V78, P15
[9]   Formaldehyde sensor using interband cascade laser based quartz-enhanced photoacoustic spectroscopy [J].
Horstjann, M ;
Bakhirkin, YA ;
Kosterev, AA ;
Curl, RF ;
Tittel, FK ;
Wong, CM ;
Hill, CJ ;
Yang, RQ .
APPLIED PHYSICS B-LASERS AND OPTICS, 2004, 79 (07) :799-803
[10]  
KAMIL M, 2004, ANAL CHIM ACTA, V518, P51