Confocal fluorescence polarization microscopy in turbid media: effects of scattering-induced depolarization

被引:14
作者
Bigelow, Chad E. [1 ]
Foster, Thomas H.
机构
[1] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[2] Univ Rochester, Dept Imaging Sci, Rochester, NY 14642 USA
[3] Univ Rochester, Dept Phys & Astron, Rochester, NY 14627 USA
关键词
D O I
10.1364/JOSAA.23.002932
中图分类号
O43 [光学];
学科分类号
070207 [光学]; 0803 [光学工程];
摘要
We present an experimental and theoretical study of confocal fluorescence polarization microscopy in turbid media. We have performed an experimental study using a fluorophore-embedded polymer rod immersed in aqueous suspensions of 0.1 and 0.5 mu m diameter polystyrene microspheres. A Monte Carlo approach to simulate confocal fluorescence polarization imaging in scattering media is also presented. It incorporates a detailed model of polarized fluorescence generation that includes sampling of elliptical polarization, excited-state molecular rotational Brownian motion, and dipole fluorescence emission. Using both approaches, we determine the effects of the number of scattering events, target depth, photon scattering statistics, objective numerical aperture, and pinhole size on confocal anisotropy imaging. From this detailed analysis and comparison of experiment with simulation, we determine that fluorescence polarization is maintained to depths at which meaningful intensity images can be acquired. (c) 2006 Optical Society of America
引用
收藏
页码:2932 / 2943
页数:12
相关论文
共 38 条
[1]
TORSION DYNAMICS AND DEPOLARIZATION OF FLUORESCENCE OF LINEAR MACROMOLECULES .1. THEORY AND APPLICATION TO DNA [J].
ALLISON, SA ;
SCHURR, JM .
CHEMICAL PHYSICS, 1979, 41 (1-2) :35-59
[2]
[Anonymous], P SPIE IS
[3]
[Anonymous], 1990, CONFOCAL MICROSCOPY
[4]
Monte Carlo simulations of the diffuse backscattering Mueller matrix for highly scattering media [J].
Bartel, S ;
Hielscher, AH .
APPLIED OPTICS, 2000, 39 (10) :1580-1588
[5]
Bigelow C.E., 2005, BIOL APPL CONFOCAL F
[6]
Imaging enzyme activity with polarization-sensitive confocal fluorescence microscopy [J].
Bigelow, CE ;
Vishwasrao, HD ;
Frelinger, JG ;
Foster, TH .
JOURNAL OF MICROSCOPY, 2004, 215 (01) :24-33
[7]
Confocal fluorescence spectroscopy and anisotropy imaging system [J].
Bigelow, CE ;
Conover, DL ;
Foster, TH .
OPTICS LETTERS, 2003, 28 (09) :695-697
[8]
Retrofitted confocal laser scanner for a commercial inverted fluorescence microscope [J].
Bigelow, CE ;
Harkrider, CJ ;
Conover, DL ;
Foster, TH ;
Georgakoudi, I ;
Mitra, S ;
Nichols, MG ;
Rajadhyaksha, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (08) :3407-3410
[9]
The orientation of eosin-5-maleimide on human erythrocyte band 3 measured by fluorescence polarization microscopy [J].
Blackman, SM ;
Cobb, CE ;
Beth, AH ;
Piston, DW .
BIOPHYSICAL JOURNAL, 1996, 71 (01) :194-208
[10]
Bohren C., 1983, ABSORPTION SCATTERIN